Belleair Air Conditioning Service
Looking for residential air conditioning repair, installation, or replacement near Belleair Beach, FL? Total Air Inc. has you covered! We’ve been serving customers in Belleair Beach since 2003 with our friendly and expert work. Our highly trained HVAC technicians are available 24/7 for any heating and air emergencies. We’re committed to keeping customers cool and comfortable, and we offer a 100% satisfaction guarantee on all of our work. So when you first notice signs of your HVAC system acting up, don’t hesitate to call us. We’ll get your air conditioner running like new in no time!
Connect with our team today at 727-822-7700 to get started on the best AC repair in Belleair Beach FL!
Air Conditioning Repair Services
Uh-oh! Feeling the heat because your AC decided to take a siesta? Fear not! Our air conditioning repair services are here to bring back the chill when the cool breeze fades away. We’re quick, efficient, and we speak fluent AC – your hero in distress.
Air Conditioning Installation, Central Air Installation, Air Conditioning Replacement
Dreaming of that perfect cool haven in your home or office? Our air conditioning installation services are not just about slapping a machine in a corner; we’re all about creating a refreshing oasis for you. Whether it’s a sleek new AC, a central air system that dances to your tune, or an upgrade that’s long overdue, we’ve got you covered.
Out with the Old, In with the New
Sometimes, you just need a change, right? If your AC is feeling a bit old-school or just plain tired, we’re your upgrade specialists. Our air conditioning replacement services ensure you say goodbye to the old and hello to a new era of cool vibes.
Air Conditioning Maintenance and Tune-Up
Keeping the cool vibes alive requires a bit of maintenance magic. Our air conditioning services and maintenance packages are like spa days for your AC – keeping it fresh, efficient, and ready to tackle whatever temperature tantrum Belleair Beach throws its way.
Commercial HVAC – Business Comfort, Serious Cool
Your business is your kingdom, and we understand the importance of keeping it at the right temperature. Our commercial HVAC services are tailored for businesses big and small, ensuring your workspace is cool, comfortable, and conducive to productivity. No more sweaty meetings or hot-headed boardroom discussions – we’ve got your back.
At Total Air, we don’t just fix ACs; we create cool experiences. Connect with us for all your HVAC needs in Belleair Beach, and let’s keep it cool together!
Recent Jobs and Reviews in Belleair Beach, FL
Our Local Reviews by City
- Belleair Beach, FL (3)
- Clearwater, FL (23)
- Dunedin, FL (1)
- Gandy, FL (1)
- Gulfport, FL (47)
- Indian Rocks Beach, FL (1)
- Indian Shores, FL (1)
- Kenneth City, FL (4)
- Largo, FL (40)
- Madeira Beach, FL (5)
- New Port Richey, FL (1)
- North Redington Beach, FL (1)
- Palm Harbor, FL (5)
- Pinellas Park, FL (29)
- Redington Shores, FL (1)
- Safety Harbor, FL (1)
- Saint Pete Beach, FL (1)
- Seminole, FL (45)
- South Pasadena, FL (18)
- St. Pete Beach, FL (30)
- St. Petersburg, FL (821)
- Sun City Center, FL (3)
- Tampa, FL (12)
- Tierra Verde, FL (12)
- Treasure Island, FL (24)
Job Locations and Reviews
Concern, Says unit is not cooling. Cause, Found nothing wrong with unit cooling properly. Customer has huge windows in front of master causing a huge heat index. Also 90+ degree weather there only so much a mini split can do. Correction, Told customer that during maintenance ( Whenever we schedule it that we will rinse condenser, but there’s really not much we can do pressures and TD are perfect.
Parts return to install condenser coil. I recharge the system after placing system on a vacuum to achieve 400 µm and recharge system with 14.11 ounces of refrigerant to achieve a 22° temp split and 8° sub cooling.
Both indoor and outdoor units were running upon arrival. Temperature split of 6.4° with 75.5 coming out of the supply. System has a refrigerant leak which was visible inside of the condensing unit. I re-verified with electronic leak detector along with the customer. Customer decided to fill the system back up so they can cool for as long as they can until the work and repair is completed. Customer also approved for us to move forward with ordering the condensing coil. Model number CBA 25UH -036–230–01 serial number is 1519H19095.
Materials added. 45/5 capacitor and two pure air X bulb replacements. Notes: performed for system tuneup. Unit was in heat mode at 73°. Explained the heat pump is creating condensation on the outdoor unit to the customer. Inspected all electrical components in cycled heating and cooling mode. Unit is a 2019 system and is equipped with two UVC germicidal bulbs. Summary: there is no date on the Pure Air X. The supply Plenum bulb is burnt, and I suggest replacement on each bulb. The outdoor capacitor is outside standard factory range. I recommend replacement to help prevent premature breakdown. I also suggest adding a primary float safety switch in case of a clogged drain. A $25 coupon was applied to the capacitor and $100 coupon was applied for the UV bulb replacements. I collected signatures and payment. This job has been completed. Thank you for choosing Total Air!
Complete prime maintenance on (2) ac systems. I inspected filter locations and changed all customer supplied filters. I cleared and flushed both drain lines with vacuum and water. I performed routine maintenance on all pieces of equipment. System 1 Downstairs: All parts and components are working properly. The air handler cabinet is clean. All indoor air quality products are working properly. System 2 Upstairs: When checking refrigerant pressures I found the system low on refrigerant. I offered to complete a leak search to pinpoint the leak. Vijay accepted. I found the evaporator coil to be leaking. I have added a video of my leak detection. We will need to order the coil and schedule the repair with Vijay. Air handler equipment info: Model- AVPEC59D14AB Serial- 1707481607 Moving forward the office will call for scheduling. Thank you for choosing Total Air!
Customer says periodically she has a very corroded smell that she smells in the air in a particular area of the home. Did a walk-through with customer and adjusted the humidity level from 65 to 55% on the downstairs thermostat. Customer changed it on her upstairs thermostat. She does not notice any difference in cooling, doesn’t notice the system struggling to cool on either upstairs or downstairs unit. My Professional opinion is that there is nothing wrong with either air conditioning system. She lives on the water and it is quite possible that a lizard or something small got inside and maybe have perished. When the air conditioning system is running it’s pushing air through the home so maybe every once in a while she catches a wiff of the smell. Both thermostats have achieved temperatures that were set. Customer will call us if there are any cooling or heating issues. Both systems are cooling properly at this time.
Replaced all uv lights in both systems. Tested all lights successfully. Job complete
Called out today to perform a precision tune up. Checked all indoor and outdoor electronics and motor components to ensure equipment is operating correctly within manufacture specifications. Checked filter and cleared drain line. Measured the temperature drop across the coil. Tightened all wire connections. Outside I removed the panels from the unit and cleaned the coil. Vacuumed drain line from outside port. Educated homeowners on the importance of annual maintenance as well as member pricing on repairs, replacement and service trip charges. Equipment is operating properly at this time. Applied tune up coupon for todays visit. Thank you for always choosing Total Air!
Performed maintenance on 2 mini split systems 6 heads in total. All electrical components are within factory spec. All heads are functioning mechanically. Pressures are at correct levels. All heads have heavy growth in them. Home owner renewed her TAPS membership and purchased service to have all 6 heads cleaned. Office will call to schedule an appointment for cleanings. 2 technicians on job preferred due to amount of cleanings.
All head units deltas are within range filters that need to be cleaned were cleaned drainage was cleared all these units are operational at this time no faults found.
Installed 2 new germacidial bulbs, 2 new economy bulbs, and 2 oxidizer bulbs. Also delivered filters. Left 2 systems in good working order.
Installed 2 new whole house germicidal units in 2 systems. Cycled and inspected equipment. Left systems in good working order.
Tear out old unit install new Bosch 5 ton unit on top of new coffin box top installation install new plenum new heat shield install new condenser on raised slab on side of house connect start up add to lb of 410A to condenser started up everything running perfectly customers happy paid up and we're done
Installed 5 ton air handler and condenser 18 1/2 see her unit number two upstairs third-floor flushed copper and drain remade Plenum flushed copper flush drain nitrogen test to 400 psi G vacuum microns below 500 started up system and charged to factory spec unit running to SPEC heater and not marked a new air handler do that we never gotA secondary heater will need to return with secondary heater and double check breakers they respond with said heater we are unsure of the amps the heater would need so we are unable to change breaker accordingly homeowner unresponsive and not able to reach customerVia call will need to contact customer to collect remaining balance
I found the system was very low on refrigerant, there is a leak somewhere in the system. I charged the system up per customer. I added 8.8 pounds of r410a refrigerant out of jug #167 and 157. I got the delta T to 20degrees. This unit is 2 years old and was installed by a different company. The customer is going to try and get them to cover the repair cost. In case they don’t, we would have to do an extensive leak search to locate the leak. The fix it and recharge the system. I couldn’t check the capacitor or clear the drain due to rain and weather conditions. Please follow up with the customer on Monday to see if the unit is still cooling properly. I left the system in good working condition, but we need to monitor the refrigerant levels.
Cycled and inspected 2-systems. Found #1 downstairs system in good working order. Found #2 upstairs system with a restricted drain line causing system to short cycle. Also found contactor pitted and run capacitor for outdoor fan motor weak. Cleared both drain lines, installed a new contactor, and run capacitor. Left 2-systems in good working order.
Take out existing condensate pumps for the main TV area and kitchen indoor unit. Install two (2) gravity feed drain lines for the indoor units. We disconnected pumps and ran new drain lines on kitchen and tv room . I tested drain operation and cleaned filters...
I found main tv area evap mini blue condensate pump was clogged with growth. I cleaned out with cleaner/ vacuumed.. Beth will like to have the main tv area and kitchen system pumps taken out , gravity feed the water in 3/4†pvc. We need to put a quote together for both drains. Beth has a contract on both systems. Need to perform a maintenance when we do the drain lines..