Safety Harbor, FL

Request Service
Google Rating
4.8
Based on 1530 reviews
js_loader

Something is not working with with NN Extensions

Please Contact Local Gladiator For Support

Residential HVAC in Safety Harbor, FL

Did your AC break down right in the middle of a Florida heat wave? Finding a reliable and trustworthy HVAC company can be overwhelming. Total Air of St. Pete is here to make your choice easy! We provide local expert AC repairs, installations, tune-ups and more to keep your Florida home cool and comfortable - always.

Air Conditioning Repair In Safety Harbor, FL

Available 24/7 for emergencies, you can count on our team to keep your home cool all long. Our expert techs are standing by waiting to come help you with your AC repair. From a quick thermostat repair to a full condenser line replacement, our comprehensive repair services are second to none in the area.

Call us anytime for fast air conditioning repairs at 727-822-7700

Air Conditioning Installation

When it comes time to replace your AC, Total Air provides central air installation services that are prompt, thorough and top-quality. You don't want second-best when it comes to such a large investment in your home. Our highly trained techs are well-versed and knowledgeable in air conditioning replacement services. We'll set you up with a new central AC system that will last for many years to come!

Our company is happy to offer affordable financing options and FREE estimates on new systems in Safety Harbor. Connect with us today to get started! 

Air Conditioning Services

Don't worry, we don't stop at just AC repairs and replacements. Total Air is your full home comfort partner! We provide complete repair, maintenance and installation services on central ACs, furnaces, heat pumps, ductless mini-splits and more. Our team even offers attic insulation installation as well as indoor air quality products and services. For your total comfort, call on the team at Total Air today!

Commercial HVAC

The HVAC services we offer extend to businesses and companies in the Safety Harbor area. As one of the leading commercial HVAC companies in the area, our services include commercial HVAC design, installation, maintenance and repairs. In a bind in the middle of the night or over the weekend? We're also available 24/7 for emergencies so you won't have to keep customers waiting.

Connect with our team today for a consultation!

We Are the Total Package in Safety Harbor, FL

Total Air has proudly served homes and businesses in Safety Harbor since 2003. Check out our reviews below to see how we achieve 100% satisfaction for every heating and air conditioning repair, replacement and maintenance job we do!

Recent Jobs and Reviews in Safety Harbor, FL

Rated 5.0 out of 5 stars based on 1 customer reviews

Job Locations and Reviews

jweidner@cassidyac.com
jweidner@cassidyac.com Checked in
Returned to check system #2. Refrigerant levels are within normal range and delta temperature is good. System is running well at this time. Explained benefits of iFlow since customer has had drain issues in the past and uses vinegar monthly. He will think about this. Both units have a supply of 59°
Safety Harbor, FL 34695
jweidner@cassidyac.com
jweidner@cassidyac.com Checked in
Upon arrival the system was not running. After inspection I found the drain line to be clogged. There is a lot of zooglia buildup in the drain. Cleared and flushed drain line with vacuum and also nitrogen. Flushed with hot water 5-7 liters. Added a union before the p-trap for easy access in the future. Highly recommend iFlow to help mitigate zooglia buildup and help prevent clogged drains. Customer declined at this time. Offered membership renewal and customer will hold off. Estimates added. Unit is now cooling.
Safety Harbor, FL 34695
Wade H.
Wade H. Checked in
System #2 was low on refrigerant. (TXV) Checked evap coil, blower fan, outdoor coil, and filter. Did a spot leak check on the system and didn’t get any hits. Customer agreed to add refrigerant (3lbs). Told the customer if this happens again we need to do a more in-depth leak check. Delta Temp is now 19.8° and refrigerant levels are within normal range.
Safety Harbor, FL 34695
Wade H.
Wade H. Checked in
Recall Drain line cleaning June 9/2023 Customer concerned about unit not cooling again. Unit had the drain line cleaning. Checked thermostat calibration and filter location. Checked blower motor operation and inspected equipment cabinet. Located the emergency drain pan full of water and float switch is tripped with water. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked drain line pitch and secure drain line in place. Recommend new safety surge protector on condenser unit to prevent voltage spikes and electrical failure on control board and compressor unit. Unit is cooling well and drains properly. Thank you for choosing total air.
Safety Harbor, FL 34695
Arionna L.
Arionna L. Checked in
Called out today due to no cooling. Upon arrival client stated when she got home from vacation the machine worked for a few hours then stopped. System kicked back on in the middle of the night. I found that the drain line is clogged and was intermittently tripping the float switch. Gave options for one time flush and go vs enrolling into a preventative maintenance plan and getting a drain solve treatment. Added drain solve to drains from the pan. Allowed that solvent to sit for 20 minutes before flushing with two gallons of hot water. Checked all electronics and motor components to ensure equipment is operating properly within manufacture specifications. Checked filter. Outside I removed the fan from the condenser and cleaned the coil from the inside out. Checked refrigerant pressures. Vacuumed drain line clear from outside port. Client stated that Performance air was out last year and added a few pounds of refrigerant. She called for a second opinion and that tech stated t
Safety Harbor, FL 34695
Review
AC went out and was able to get someone out here on the same. The repair did require more work/repair but scheduling the second visit was easy and quick turn around. We use total air maintenance and it’s always worth the yearly plan and certain affordable.
Lindsay - Safety Harbor, FL 34695
Nathan R.
Nathan R. Checked in
Complete installation of (1) condensate pump. We installed the new pump and ran copper through the attic inside the line-set cover to the outside for drainage. Cycle and tested pump for proper operation. Complete installation of (1) nest thermostat. Cycled the thermostat in all modes. Left system in good working order. All pictures are uploaded. Customer signed up for another year of maintenance. Thank you for choosing Total Air!
Safety Harbor, FL 34695
Nathan R.
Nathan R. Checked in
Complete no cool call. **Customer states the drain line keeps backing up. Customer just moved into this new home a few days ago. He is a current maintenance member but hasn’t got the chance to switch his membership over to this address. We will need to switch the maintenance to this address. There is a brand new HVAC system installed as the system and drain line are new. After inspection I found the drain line to be leveled incorrectly and is ran under the flooring which we can not access the line. The drain line travels at an incline going outside which will not work. Gravity fed drain lines needs 1/4” of pitch every 4 feet. This does not. We will have to run a new condensate pump system from the air handler to the exterior of the home to restore proper drainage. Customer signed off for the full condensate pump conversion. This will need 2 guys. (1) 25ft roll of copper. Customer is down until we can make the repair. *I sold a drain line clearing but this will need to be
Safety Harbor, FL 34695
Jeff B.
Jeff B. Checked in
Returned to replaced burned defrost board. Located short in y wire that caused board failure. I was able to jump y over to another wire to correct short. While cycling the system, I found the system running cooling when no cooling call was made and should be running heat mode at the condenser. I tried the other available wires in the bundle with no success. We will need to return to pull a new low voltage wire from airhandler to the condenser (carrier system). Wire will need to go straight up the wall and through the soffit. Job will take 2 techs and 2 to 3 hours to complete. Office to make sure techs have a way to secure the wire to the wall with clips. System bypassed in cooling mode for now. Heat will not function until wire pulled. Home owner prepaid wire pull today.
Safety Harbor, FL 34695
Jeff B.
Jeff B. Checked in
No heat Found defrost board shorted and burnt. Carrier system. Uploaded model serial pic uploaded. Office to verify warranty and part availability. Office to schedule repair. System down until repair completed. Homeowner aware repair estemate only valid if warranty is good.
Safety Harbor, FL 34695
Jeff B.
Jeff B. Checked in
Need to reschedule with smaller technician to fit through closet scuttle. <br> <br> <br> Wadeh<br> 12/29/2022<br> <br> <br> Customer concerned about unit not heating properly. Checked thermostat calibration and filter location. Checked blower motor operation and inspected equipment cabinet. Found Easy acces with pull down latter. Located 5 amp fuse burnt out and failed. Replace fuse and checked unit operation. <br> <br> Fuse is still tripping, has low voltage short in low voltage wiring. Checked all wiring connections and located outside thermostat wiring is touching the ground and the wire is bad. Choose extra wiring and hook up low voltage wire orange. Test unit operation and unit is cooling well and running heating properly. <br> Highly recommend new germicidal uvc light to prevent biological growth in air handler coil. <br> Recommend new safety surge protector on outside condenser unit to prevent voltage spikes and electrical failure on control board. <br> <br> Suggest new Taps
Safety Harbor, FL 34695
Jon C.
Jon C. Checked in
Arrived at customer's house for system inspection. On arrival customer showed me to 2 air handler systems. Checked system number 1. UV light was past change date. Brought this to customer's attention and suggest we change it. Customer agreed. Change out light and unit now working fine. Check under evaporator coil and evaporator coil was clean.. Unit was producing proper Delta T. Went to next air handler unit and UV light was also past date. Do not have replacement for this bulb on the truck but got unit information. Customer would like to change out Whenever we can get the bulb. Checked under evaporator coil and under evaporator coil was clean. Suggested to customer both of these lights be upgraded to a pure air UV light. Gave customer literature and created estimate. Next went outside to condenser's. Opened electric cabinets And tested all components. Capacitors within acceptable range. Contactors sending propper voltage. Vacuumed out both drain lines. Neither unit is currently equipp
Safety Harbor, FL 34695
Wade H.
Wade H. Checked in
Arrived at customer's house for system inspection. On arrival customer showed me to air handler unit. Open up cabinet and saw biogrowth on the motor and on motor wiring. Suggested customer get IAQ you're get IAQ. Customer would like to do research before making decision. You know it was putting out proper Delta T. Under evaporator coil was clean. Next in period next went outside to condenser and hooked up gages. All pressures and readings were of acceptable range. Contact or sending proper voltage. Capacitor within acceptable range. Vacuumed out condensate line. Unit checks out. Gave report to customer and customer was happy with report. Collected payment and signature and left. Customer happy.
Safety Harbor, FL 34695
Wade H.
Wade H. Checked in
Unit #1 for 2nd floor Upon arrival customer showed me an air handler in the 2nd floor closet that needed turned up. The evap coil is clean. Cleared the condensate with nitrogen and solvent. Checked the system for proper amps and voltage. Went to the condenser the check proper amps and voltage. Recommended a pure air X and surge protector Unit #2 for 1st floor Upon arrival customer showed me an air handler in the 2nd floor closet that needed turned up. The evap coil is clean. Cleared the condensate with nitrogen and solvent. Checked the system for proper amps and voltage. Went to the condenser the check proper amps and voltage. Capacitor under factory specs. Customer needs a elite build. Customer denied all work. Did recommend a pure air x and surge protector.
Safety Harbor, FL 34695
matt@totalairinc.net
matt@totalairinc.net Checked in
Upon arrival checked motors, electrical components, and pressures on 2 rheem split closet systems. AH 1 AND 2 both upstairs. Upstairs IV bulb still on but needs replaced. Replaced UV bulb on larger rheem unit AH (both AH next to each other). Cleared draon line and DeltaT excellent. Recommend Surge protectors for both units. Added existing equipment and left systems in good operating condition.
Safety Harbor, FL 34695
Brian R.
Brian R. Checked in
I performed a maintenance. I checked pressures, electrical components and flushed drain line with cleaner. The warranty capacitor was below factory specs, replaced. I noticed the compressor is slightly noisy on start up. Need to keep an eye on this issue. I left the system in good working order..
Safety Harbor, FL 34695
rigo@totalairinc.net
rigo@totalairinc.net Checked in
Installed the filter and a uv light bulb.
Safety Harbor, FL 34695
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos.
You and your service location:
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*
Back Next