Book Now
Book Now

Gulfport, FL Air Conditioning and Heating Services

Total Air, Inc.

Rated 5.0 out of 186 reviews

Air Conditioning Repair In Gulfport, FL

If your air conditioner is no longer keeping your home cool, save yourself the headache and give Total Air Inc. of St. Pete a call. We have been providing  service, maintenance and AC repair in Gulfport, FL since 2003.

We Specialize In Not Only Repairs But Also:

We hold our technicians to a high standard of service and courtesy. We know the last thing you want to do during a hot summer is call an air conditioning repair company, so we can promise you will be greeted by a friendly, focused expert. We offer 24/7 service, so we will fix your AC on your schedule. We have some of the most experienced HVAC specialists in the area, so you can rest assured you are in good hands with Total Air. Our 100% customer satisfaction guarantee proves this!

Unbeatable AC Service Prices

We understand that the nature of AC emergencies is they are unexpected. And often this is not because of anything you did. No one in the Gulfport area should be expected to pay outlandish prices for something as unpredictable as air conditioning repair! At Total Air, we offer highly competitive pricing on our services. We are also able to offer a variety of different financing options (with approved credit) through our relationship with Wells Fargo. Additionally, our experts are extremely knowledgeable in maintenance techniques and tricks that can help you cut back on your need for repairs, which keeps your bill down.

Things To Consider Before AC Repair

Sometimes the trickiest aspect of air conditioning repair is deciding whether or not you actually need it. We are here for whenever you may need us, so it is important you know when to call. Here are a few of the telltale signs you should contact your Gulfport AC repair professional.

  • Your energy bills are climbing, and you can’t figure out why. While an HVAC unit may still be running, its energy efficiency can rapidly deteriorate over time.
  • Different rooms or areas of your home are hotter or colder than the rest. An air conditioner that is working properly should be able to heat every corner of your house.
  • You finding yourself dusting more frequently than you used to. If your AC has a leaky duct, it could be clogging up your home with dust and debris.

If you find yourself experiencing any of these oddities, don’t hesitate to let Total Air handle your air conditioning repair needs. We can bring your home from hot and stuffy to cool and clean in no time. Our respectful technicians will perform whatever service your home requires with a smile on their faces and at an affordable price.

Call us at any time at (727) 822-7700 for a free second opinion or estimate.

Local Reviews
for Gulfport, FL

Total Air, Inc. Rated 5.0 out of 5 stars based on 15 customer reviews

Map of Gulfport, FL

A/C Air handler duct repair




Review of Total Air, Inc.

Another professional job performed by Total Air. Josh and Zac were prompt, courteous (wore their masks at all times), clean and performed the repair professionally.


Map of Gulfport, FL

Great service, fast , efficient !!




Review of Total Air, Inc.

Will use again ! Took 7 years to fix problem and Alex did it in 1 hour !


Map of Gulfport, FL

Top of the line service




Review of Total Air, Inc.

My a/c quit working. I called and the came out that same day. Checked system and found blower motor died and order the motor right away and had it delivered asap. Came back the next day and replaced motor and my a/c was back up and running. Great service.


Map of Gulfport, FL

Thank you!!




Review of Total Air, Inc.

These guys did a great job. The price was not bad and I’m very happy with my new ac unit. Thank you.


Map of Gulfport, FL

Good




Review of Total Air, Inc.


Map of Gulfport, FL

Great




Review of Total Air, Inc.

Real good, super nice guy.


Map of Gulfport, FL

On time and thorough




Review of Total Air, Inc.

Sergey and Brian were personable and professional. They were both very thorough in troubleshooting my issues. They also were very helpful in providing general maintenance information.


Map of Gulfport, FL

Good service.




Review of Total Air, Inc.


Map of Gulfport, FL

Great service as usual.




Review of Total Air, Inc.

Great job, as always


Map of Gulfport, FL

Two houses, three systems




Review of Total Air, Inc.

Again, the best care from Total Air and Raiko.


Excellent service




Review of Total Air, Inc.

Professional, knowledgeable, highly recommend.


Always great service and very professional!




Review of Total Air, Inc.


Great




Review of Total Air, Inc.

Very professional as always. Was also very knowledgeable. Better keep him on staff.


Excellent Service and Professionalism!




Review of Total Air, Inc.

Nevon is a wonderful representative for Total Air! The service was thorough; and, very professional. I enjoyed having Nevon in my home and feel very confident in the safety and condition of my heat and air systems. Thanks so much!


Very Helpful and knowledgeable




Review of Total Air, Inc.

Rigo is very good and I will recommend everyone at Total Air!


josh@totalairinc.net

josh@totalairinc.net

Upon arrival found that the supply plenum is leaking air and creating condensation that is dripping off on the sealing. Under side of the supply plenum is wet. Recommend replacing a piece of the button section of the supply plenum that is wet and sealing it properly. Peter took steps to avoid further damage until repairs are made. He would like to pay service call fee over the phone and get a quote of the repair. Cut off 50 in of underneath side of plenum soaking wet replace tape glue Mastic re-hang let mastic dry Andre mastic again

Near 59th St S, Gulfport, FL 33707
Bryan F.

Bryan F.

Completed tune up on system, I checked all electrical components and motors. The wall the thermostat is mounted on was not sealed, thermostat wasnt reading correct temperature causing system to run constantly. I reccomend replacing thermostat and sealing wall penetration. Customer approved. I replaced the thermostat and sealed the penetration. Went through start up procedures. I cleared and primed the drain line. Uploaded pictures to service titan

Near 9th Ave S, Gulfport, FL 33707
Sergey G.

Sergey G.

Customer said the condenser tripped a breaker and I was here to check everything and find out why it tripped. The customer said he was clearing out the drai line because the float swith had tripped. I checked all electrical components and motors. All motors have a good amp draw.the pressures are a bit high 329 psig ( r-22). I think the customer had tripped the float quickly for a second and the compressor turned back on too fast, therefore over amped the compressor, in turn that's what tripped the breaker. The air handler has a dirty blower wheel. I strongly recomend we pull and clean it . I checked the compressor and odfm on the way out and they are still drawing good amperage. J left the system in proper working condition. The customer had a 25$ off coupon.

Near Gulfport Blvd S, Gulfport, FL 33707
Justin A.

Justin A.

Upon arrival performed maintenance. Inspected systems electrical components, coils, pressures, and cleared drain line. The dual run capacitor was reading low MFD, we recommended on replacing and we moved forward. Talked about UV light options because of the traces of growth, he wants to move forward next time on that. Left system in good working order.

Near 18th Ave S, Gulfport, FL 33707
Sergey G.

Sergey G.

I added 3 pounds of r427a refrigerant out of jug#62. Got the deltaT to21Degrees. The customer wants to replace the system and add a germicidal. I spoke to Bryan and we will set up an appointment with the customer to give him the estimate. I installed a new T-6 thermostat. Cleared the drain and loaded equipment information and pictures to service titan. If the customer chooses to replace, please credit him the service call fee, the refrigerant and the thermostat. I signed him up to a year maintenance with us, so please schedule a maintenance as soon as possible. I left the system in proper working condition. We will need to monitor the refrigerant levels on our next visit.

Near Havana Ct, Gulfport, FL 33707
Nevon H.

Nevon H.

I cleaned the evaporator coil in place. I cycled and monitored the system, checked for proper pressures and temperatures. The system is cooling much better. She declined replacing the thermostat for now because it seems to be working better but if it starts reading the wrong temperature again she will contact us. Customer will continue to monitor the system.

Near 51st St S, Gulfport, FL 33707
Sergey G.

Sergey G.

Upon my arrival I found that the blower motor had failed. I ordered a new motors and it should be there tomorrow. I signed the customer to our maintenance program and loaded all my equipment information to service titan. Left the system off till we come back with the new motor. We need to charge a service call fee 49.95 and for the motor and 1 year membership tomorrow. I changed out the blower motor and performed start up procedures. I checked the amp draw on all motors and the y were all good. The unit was double filtered I removed one of the filters and advised the customer to leave just one in. My delta T is at 21°. I cleared out the drain line and left the unit in good working condition.

Near Horan Way S, Gulfport, FL 33707
Jason D.

Jason D.

Cycled and inspected equipment. Found system off on safety switch due to a restricted drain line caused by drain line with no p-trap. Cleared drain line and installed a new p-trap. Left system in good working order. Also customer purchased maintenance agreement 1-year 1-system.

Near 28th Ave S, Gulfport, FL 33707
josh@totalairinc.net

josh@totalairinc.net

14 SEER Amana/Goodman System 14 Seer Amana straight cool system on Hurricane pad with cinder blocks and hurricane pad then unit strapped install new air handler on new hanging kit install plywood on floor in front of air handler go to City Electric and purchase 15 amp Siemens breaker and 45 amp Siemens breaker for system startup everything running in perfect condition

Near Tangerine Ave S, Gulfport, FL 33707
Nevon H.

Nevon H.

I found multiple issues. The evaporator coil is dirty and needs to be cleaned. Not getting a proper pressure and temperature readings. The thermostat is reading the wrong temperature. It reads 94 degrees and I measured 79 degrees in the house. The air filter is the wrong size (too small). It’s a 12x20x1 and it’s supposed to be 12x24x1. I recommend cleaning the evaporator coil in place w/ the coil machine, replace the thermostat and recheck the pressures and temperatures. Customer will get the correct filter. The system is from 2007 (13 years old) and I asked her to consider replacing it due to age, wear and tear. They will consider it but for now she approved to move forward with the work and I confirmed with the office to schedule for Friday, July 17th. Customer asks if there is an earlier opening in the schedule, to please contact and let her know. They used a $50 gift card towards the work and will consider purchasing a TAP membership.

Near 51st St S, Gulfport, FL 33707
raiko@totalairinc.net

raiko@totalairinc.net

Upon arrival found a partially restricted drain line and a drain pan full of water in the attic. Customer ( Tenant ) approved me to clear the restriction and the drain pan. I also found other issues. Ductwork has multiple non repairable holes and retur and supply plenums are extremely damaged by rats. Recommend replacing entire ductwork. Also found that the suction line is missing most of the isolation and water fin condensation is dripping on the sealing. The system is 18 years old and in poor overall condition. I would highly recommend replacing the system and ductwork due to the poor overall condition. Cleared the drain, left system running. Customer would like a quote on ductwork.

Near 53rd St S, Gulfport, FL 33707
Nevon H.

Nevon H.

We inspected the system, cycled and monitored it. The system is very old from 1983 (37 years old), with very poor efficiency, wear and tear, deteriorated evaporator coil and a little low on refrigerant. The duct system is also old. I highly recommend replacing the system and duct work. The customer would like an estimate and we confirmed for tomorrow, Wednesday 7/8, for 10-12 arrival time.

Near 51st St S, Gulfport, FL 33707
raiko@totalairinc.net

raiko@totalairinc.net

On this visit I inspected two systems a mini split and a regular split system. Mini split was very low on refrigerant, is 9 years old and on poor overall condition. Customer approved to charge it up with 5 lbs of R410A to get them going but I recommend replacing the system since oil traces can be found at the drain line suggesting a leak on the evap coil. Coil and blower assembly are a little dirty. No more issues were found. Split system was also low on refrigerant added 2 lbs of R410A. Inspected all electrical components and found no issues. Evap coil picture not possible. Tested heat mode with no issues. Customer provided a thermostat for me to install but was faulty, he is going to return it, declined one of ours. Cleared the drain lines, left systems running.

Near 54th St S, Gulfport, FL 33707
Justin A.

Justin A.

Upon arrival performed maintenance on 2 systems. Inspected electrical components, coils, pressures and cleared and primed both drain lines. The inside of both air handlers were coated in biological growth. The up lights in the systems were operational but the bulbs were burnt out. Recommended on pulling and cleaning the blower assembly. At the condenser both start capacitors were reading very weak. The dual run capacitors were also reading weak. The contactors were all pitted and burnt (2 per system.) Recommended on all the repairs and a membership, we did not move forward with any repairs at this time. Bryan is coming out on Thursday July 9th between 3-5pm for an estimate on new systems. Left both systems in working order.

Near Skimmer Point Blvd S, Gulfport, FL 33707
Jason D.

Jason D.

Cycled and inspected equipment. Found evaporator coil, condenser coil, and filter impacted. Also found dual capacitor weak and and contactor pitted. Spoke with customer in regards to repair vs replacement. *LEFT SYSTEM NOT COOLING* Recommend: replacing system due to cost of repair, age, and overall condition of equipment or pull and clean evaporator coil, deep clean condenser coil, new contactor, and new dual run capacitor. I spoke to customer and they are interested in getting a quote for a new energy efficient a/c system to be installed with a 10 year parts warranty. I stated to customer if they move forward with purchase we will credit back there service call fee of $79.95 from today’s visit. Hillary stated to call after 11:30 a.m. tomorrow to schedule a free quote.

Near Tangerine Ave S, Gulfport, FL 33707
Brian R.

Brian R.

I found system was frozen. I keep the blower on while I replace failing parts. I replaced pitted/ burnt contactor, weak dual run capacitor. On start up the condenser fan motor failed. I replaced with a rescue motor with new mini turbo. I vacuumed drain line with cleaner.. I found the original washable filter in system with 10 years of dust and dirt. Now they have better air flow.

Near Preston Ave S, Gulfport, FL 33707
raiko@totalairinc.net

raiko@totalairinc.net

Upon arrival found a failed dual capacitor at the condenser. Customer approved repair, replaced the capacitor and performed start up. System was a little low on refrigerant, added 1 lb of R410A. Coil is clean , found no more issues, cleared the drain line. Left system running properly.

Near Hull St S, Gulfport, FL 33707
Brian R.

Brian R.

I found the drain line that goes into the washing machine drain was plugged up. I blew nitrogen and flushed with cleaner.i checked electrical components and pressures. They have a membership.. note: we offer uv light that we will install inside the air handler to kill germs,viruses,and bacteria. I will email two options..

Near 23rd Ave S, Gulfport, FL 33707
Brian R.

Brian R.

The owner said water was sitting to the left of the system drain. Looking at the head it’s lower to the left. I took pics, tested with water which drained properly. I checked head with level (perfect). The ceiling is off by 1/4”. That makes the head look off level.

Near Del Rio Way S, Gulfport, FL 33711
raiko@totalairinc.net

raiko@totalairinc.net

Upon arrival found the system low on refrigerant, performed a leak search and found multiple refrigerant leaks at the evaporator coil. Recommendations: -Replace coil under warranty Materials Coil, liquid line dryer, about 6 lbs of R410A. "Two techs are needed for this job due to coil location". 6 hour labor. Note: Called JohnStone, coil is not at the store they will call our office ones the figure where is one and how lomy would it take. Contact them back by noon if they haven't contacted us yet. Keep customer informed(they requested).

Near 59th St S, Gulfport, FL 33707
Justin A.

Justin A.

1. Perform evaporator coil pull and clean on two (2) units. 2. Perform start up procedures. ****THIS QUOTE DOES INCLUDE TIME ALREADY SPENT FOR DIAGNOSIS**** Had to sand part of the drain pan down spray glue and silver tape it because it was rusted out. This may be an issue down the road. Furnish and install one (1) heat sequencer.

Near 49th St S, Gulfport, FL 33707
Justin A.

Justin A.

Upon arrival inspected both systems. The first system the condenser isn’t running due to the capacitor. We need to pull and clean the Evaporator Coil, replace the condenser fan motor and blade, as well as the contactor and capacitor. The second system is running but the Evaporator Coil needs to be pulled and cleaned, and the contactor and capacitor need to be replaced as well. 1. Furnish and install one (1) condenser fan motor. 2. Furnish and install one (1) condenser fan blade. 3. Furnish and install one (1) dual run capacitor. 4. Furnish and install one (1) 40amp contactor. 5. Perform start up procedures. ****THIS QUOTE DOES INCLUDE TIME ALREADY SPENT FOR DIAGNOSIS**** Replaced both contactors as well as both capacitors. Replaced fan motor and fan blade. On start up found system 5 pounds low on 427a refrigerant. Added back into the system. We will reach back out to reschedule the pull and clean on the Evaporator coils.

Near 49th St S, Gulfport, FL 33707
Casey K.

Casey K.

Installed 2 ton 14 sear heat pump reattached Plenum’s ran brand new three-quarter three eights copper flush drain line condenser on padlock pad 16 inches above level in home installed T6 change one breaker unit running to factory spec customer satisfied will have to contact customer for install date I mean inspection date

Near 12th Ave S, Gulfport, FL 33707
Brian R.

Brian R.

I found the main circuit board in condenser failed due to a dead lizard which shorted out board. I called Goodman supply many times in Clearwater and Tampa branches with no answer. We need to give them a quote. Need to see if the system is under warranty.. the office will put a quote together...

Near 20th Ave S, Gulfport, FL 33707
Brian R.

Brian R.

The evap coil is in really bad shape. I went over options . They will let the system ride out for now.. they are not ready to replace system..