Dunedin, FL

Request Service
Google Rating
4.8
Based on 1540 reviews
js_loader

Something is not working with with NN Extensions

Please Contact Local Gladiator For Support

Air Conditioning Repair in Dunedin, FL

If you’re in need of air conditioning repair, installation, or replacement, look no further than Total Air Inc. We have been proudly serving the Dunedin, FL, area since 2003 and are committed to keeping our customers cool and comfortable. Our highly trained HVAC technicians are available 24/7 for any heating and air emergencies you may have. We offer a 100% satisfaction guarantee on all of our work, so when you first notice signs of your HVAC system acting up, don’t hesitate to call us. We’ll be quick and dependable, getting your air conditioner back up and running in no time.

We provide:

Give our team a call today at 727-822-7700 to get started. We look forward to keeping you comfortable in your Dunedin home all year long!

Recent Jobs and Reviews in Dunedin, FL

Rated 5.0 out of 5 stars based on 1 customer reviews

Job Locations and Reviews

Review
Very professional.very patient in answering all of my questions. Total Air is lucky to have a great employee.
Satisfied customer - Dunedin, FL 34698
Casey K.
Casey K. Checked in
New line set, new electrical wiring, new drain line, new wall mount stand or outdoor mini split, all permits and inspections included. Comes with remote.
Dunedin, FL 34698
Wade H.
Wade H. Checked in
1475.83 Out to replace the outside condenser unit fan motor and installed new turbo 200 x capacitor in the condenser unit. Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked electrical wiring and checked electrical components. Capacitor has tested good and working properly. Checked refrigerant levels and check discharge temperature. Unit is cooling well and drains properly. Thank you for choosing total air.
Dunedin, FL 34698
Wade H.
Wade H. Checked in
Customer concerned about unit not cooling properly. Checked thermostat calibration and filter location. Customer has replaced filter. Checked safety float switch and inspected drain line. The drain line is dry and working properly. Checked blower motor operation and inspected equipment cabinet. Checked outside condenser unit and located the run start capacitor is bad and needs to be replaced. I have replaced capacitor in condenser unit and checked system operation. After running for 3 mins the condenser fan motor has stopped and tested bad. The condenser fan motor needs to be replaced. Tempstar Model # M4hp4048a1000ab Serial # 180540140m Customer has approved for new fan motor and new capacitor. Customer has declined membership at this time. Office will follow up with new motor replacement and return to repair system. Thank you for choosing total air.
Dunedin, FL 34698
Arionna L.
Arionna L. Checked in
Called out today to perform a precision tune up on a year old system. Checked all electronics and motor components to ensure equipment is operating properly within manufacture specifications. Checked filter, Evaporator coil is clean. Cleared drain line. Drain line was heavily impacted. Used two gallons of water and solvent to clear the drain. Measured temperature rise across the coil. Tested float switch. Outside I checked refrigerant pressures. Took amp draws. Vacuumed drain line from outside port. Surge protector is out of warranty. This is the last visit on this years maintenance agreement. Installed surge protector and renewed preventative maintenance agreement. Equipment is operating properly at this time. Thank you for always choosing Total Air!
Dunedin, FL 34698
Austin H.
Austin H. Checked in
Upon arrival to system I was shown to an HVAC system that was having trouble reaching the thermostat desired temperature. Put gauges on the system to verify the systems refrigerant levels which are fully within range of specifications at this time. Went up into the attic to the A/H for further inspection and found the systems return plenum to be falling off the unit. The unit is currently pulling in attic air from the bottom. The unit has also pulled in a significant amount of debris into the evaporator coil, I suggest a pull and clean on this system’s evaporator coil. During the hottest point of the day the attic can reach 140 degrees. With the unit pulling in this hot of air into the system it will never reach its desired temperature. I added an estimate to the invoice to be able to repair the return plenum with the proper materials. The system is currently operating in the cooling mode and the thermostat is at 79 degrees. The homeowner will not be moving forward with work today,
Dunedin, FL 34698
Jeff B.
Jeff B. Checked in
1 time maintenance Completed maintenance on one of 2 systems in the home (upstairs 4 ton). Checked all electrical components for proper volts and amp draw. Both fan motors and compressors tested good. System pressures and temperatures are correct. Electric heat kit is working properly. Cleared drain line and added solvent to break up any debris. Air handler has very heavy biological growth. The system has an economy uv light and Reme halo system with expired bulbs. I discussed options for cleaning, replacing bulbs, and upgrading to a medical grade uvc light system. I have attached quotes to the invoice for these options. Home owner also wanted a quote to change out the float switches from a circuit style to a standard float switch. Due to age and condition of the system I also discussed replacing the system. The home owner just moved in and would like to wait to replace until a later date. Homeowner declined maintenance program at this time. System cooling at this time.
Dunedin, FL 34698
Nathan R.
Nathan R. Checked in
Complete evaluation of the duct system. After inspection I found the duct work compromised. All of the outer jackets have been torn away exposing the insulation inside the duct and the inner liner which the air travels through. Some ducts are kinked due to them being hung improperly. The ducts are also not sealed. This is a 7-8 drop system with a free air return. The attic is huge. No new supply plenum is needed as what is there is fine. I talked with Bailey and she said she will get with Kip to see if we can approve the job as we typically do not install duct work in the heat of the summer. The office will reach out first thing Friday morning to update the customer. If the install is approved we will need a comfort advisor to come out asap Friday to provide an estimate on the duct replacement. If the duct job is approved the service call fee will be credited back. All pictures are uploaded. Thank you for choosing Total Air!
Dunedin, FL 34698
Arionna L.
Arionna L. Checked in
Called out today due to no cooling. There are two systems in the home. The compressor on unit #1 is short cycling. Checked refrigerant pressures. System is low on R22 and compressor has been damaged due to the leak. Explained to client that in order to repair this machine you would have to perform a leak search, repair the leak and recharge the system. Even after the leak was repaired.. the compressor is still severely damage due to refrigerant loss. Client is selling the home and is not interested in replacing the system. He is aware that the cost of repairs will range from 2,500$ - 3,500+. System is 8 years past warranty and R 22 is no longer manufactured as of 2020. Left system off at disconnect. Thank you for always choosing Total Air!
Dunedin, FL 34698
Tom L.
Tom L. Checked in
Upon arrival customer told me the ac was shutting down and ON. I put gauges on and the and the high side was really high. I took an amp drawl and the compressor is over amping a lot. The compressor is going bad. All fan are working good. I recommend on replacing the unit do to age but also quoted out a compressor. There is no guarantee that there is anything else wrong with system. Customer wants to think about it and call us back.
Dunedin, FL 34698
Casey K.
Casey K. Checked in
Installed 2.5 ton rude split system air handler on brand new air handler stand with filter rack condenser on padlock pad foundation built up for flood zone change breakers accordingly 30 amp for air handler and 25 amp for condenser flush copper flush drain treated drains drain self-insuring drain was draining properly system held pressure over 400 psi G and vacuum below 500 µm released pressure and charged system to factory spec walked customer through on their brand new Honeywell T6 thermostat and ensure customer with fluid on operating their brand new HVAC system customer paid balance in full via credit card added 2 pounds of refrigerant to system to ensure proper chargeSystem is operating to factory spec we will need Joel to come on site to post a permit when we receive one besides that job is completed
Dunedin, FL 34698
Jeff B.
Jeff B. Checked in
Evap Coil replacement not under warranty, Replaced micro channel evaporator coil. Vaccuumed line set and adjusted charge. System did not need refrigerant added. Leak was very small and unit was slightly overfilled on last visit. Rebuilt drain line. Sealed filter rack door. Installed float switch on secondary drain outlet. Tested system. Pressures and Temps are correct. Condensate drain flowing better after rebuilding it properly. System operating normally at this time.
Dunedin, FL 34698
Jeff B.
Jeff B. Checked in
No cool Found system low on 410a refrigerant. Rechecked pressures after 10 minutes and pressures continued to drop indicating the system was freezing. Found oil in drain line indicating a leaking evaporator coil. System is a Frigidaire mixed coil system these systems are prone to evaporator coil leaks. Refilled the system for temporary cooling. Homeowner is aware that the system will continue to leak until replaced or repaired. I discussed repair versus replace on a 10 year old system with no warranty. He would like a quote for both so he can decide how he would like to move forward. Office to build repair quote and call to set an appointment for our comfort advisor to come by. System is cooling at this time. Model b6bmm036kb Sn. B6d130117270
Dunedin, FL 34698
Nathan R.
Nathan R. Checked in
Complete repairs to ac system. Remove old metal return duct that is crushed and not sealed properly. Replace with 14” flexible duct. Remove all insulation from coil and clean in place. Clear and flush the drain line. Left system in good working order.
Dunedin, FL 34698
Jeff B.
Jeff B. Checked in
No cool/ loud motor. Looked over entire 4 head mini split system. Between apt a and apt b. 3 of the 4 fan motors are making bearing noise while in operation. The blower motor in apt a bed room is exceptionally loud. 2 of the four heads have been cleaned but likely not fully. The other 2 have not been cleaned in some time. The condenser should be cleaned as well. There is debris starting to build up on the coil. The condenser coil can be cleaned during a normal maintenance at no extra charge. The indoor heads would need to be disassembled and thoroughly cleaned. This is a separate charge due to high amount of labor involved. Office will need to source motors and availability on 3 blower motors. Both in apt be and the kitchen unit in apt a. Office to contact owner with estimate for repair. I added quotes for maintenance program and for 4 mini split head cleanings. System cooling at this time.
Dunedin, FL 34698
Wade H.
Wade H. Checked in
Called out today due to ductwork being deattached. Upon arrival there were two large gaps in the return vents. Repositioned and taped gap shut. Used other pieces of loose duct work to try and make a seal at the bottoms. Client is aware that the coil is impacted due to the ductwork not being sealed. They are interested in investing in a UV light and applying the cleaning the same day. Clients are on scheduled to replace ductwork in November. Equipment is operating properly at this time. Thank you for always choosing Total Air
Dunedin, FL 34698
Wade H.
Wade H. Checked in
Was scheduled to go out to customers at 5 o'clock. GPS said I would not get there before 535. Saw customers know where they would not be available after 6. Called customer to see if it would still be OK for us to come and customer has chosen to reschedule for Thursday or Friday. Would like a call from the office to schedule time schedule time for service. Arrived at customer's house for System not cooling enough. On arrival customer showed me to air handler unit. Put thermal probe on supply and unit was creating excellent Delta T. Next looked inside the cabinet and the cabinet was clean. looked under evaporator coil and evaporator coil was also clean. Filters inside were clean. Next went to condenser unit And hooked up gauges. All pressures and readings are of acceptable range. Contact or sending proper voltage. Capacitor within acceptable range. Vacuumed out drain line. Unit is performing excellent. Went inside and got temperature readings from 3 warmest rooms. All rooms were prod
Dunedin, FL 34698
matt@totalairinc.net
matt@totalairinc.net Checked in
No cool Thermostat blank. Wires to thermostat are powered normally. Homeowner paid for a replacement honey well t6 wifi stat. I installed a non wifi Tstat for temporary cooling and heating. Home owner would like an appointment on thursday 11/18 if possible. Cycled system and is working properly now
Dunedin, FL 34698
Josh W.
Josh W. Checked in
Amana ASZ14 Heat Pump 3 Ton. Install air handler on new hanging kit. Install uv light. Change breakers according to size. Install t6 thermostat. New condensor on new pad. Customer satisfied!
Dunedin, FL 34698
Alex W.
Alex W. Checked in
Performed routine maintenance on older split system checked amps volts drain lines capacitors refrigerant pressure etc. system is starting to show its age would recommend system replacement in the near future. For now system is in good working order
Dunedin, FL 34698
Kyle C.
Kyle C. Checked in
Required Repairs: These are the minimum services required to get your system running today and does not include any recommended actions that I noticed. Recommended Service +: This includes the required repair to get your system running today and recommended service to items that I noticed also need some attention. I have also included solutions to extend the life of your system and protect it from future breakdowns. I am able to complete these tasks today at a discounted rate, shown below. Air handler inspection complete volts amps are within range ECM Tate motor. Coil bright and clear. Economy UV bulb has burnt out recommend replacement client has agreed. Technician does not have bulbs in stock on truck must return to install. Condenser inspection complete volts amps and microfarads within range contactor bright new capacitor recently installed. This unit is operating at this time no faults found. Must return with economy UV bulb to install. Tuneup complete.
Dunedin, FL 34698
Josh W.
Josh W. Checked in
Tear out old unit install new 3 ton 15 Seer heat pump on new hurricane pad new disconnect 4 condenser install new air handler on new hanging kit hookup plenums with new heat shield on Supply and return mechanical fasteners splice onto low voltage wire up wiring two flow switches one in line one pan tape and Mastic plenums secure drain lines and drain pan put P-trap outside start up everything running in perfect condition collect and got signatures finished job
Dunedin, FL 34698
Kyle C.
Kyle C. Checked in
Found not heating due to bad 10mfd blower motor run capacitor. Replaced with turbo mini. Checked operation. Left system operating. System in poor condition. Lots of microbial growth and lots of rust and corrosion.
Dunedin, FL 34698
Casey K.
Casey K. Checked in
Cleaned upstairs and downstairs evaporator coil’s downstairs removed wet section bottom of return replaced and sealed cleaned and sealed upstairs air handler as well as downstairs air handler installed UV 24 V system in each air handler collected payment customer satisfied
Dunedin, FL 34698
Brian R.
Brian R. Checked in
I performed a maintenance on both systems. I found some growth on evap coils. The coils/ primary pan pans need to be cleaned in place. I sprayed some cleaner/ sanitizer inside air handlers. I checked pressures, the 2nd fl system is 1lb low on 410a. My superheat is 33degs. I hosed down condenser coils of pollen. I vacuumed out drain line with cleaner. The 2nd fl drain line was very dirty. We discussed about uv lights. They will like to move forward on the economy uv light on each air handler. The 1st floor return plenum bottom base has some growth and at one time water was dripping and ruined the bottom base. Need to put in new bottom base with a new duct board, then sanitize the box.. The second floor system does have wear and tear due to age.. The office will reach out to set up appointment for work that needs to get done.. Doug will like the phone number to our duct cleaning guy we use. He is interested in having the ductwork cleaned.
Dunedin, FL 34698
Justin A.
Justin A. Checked in
Upon arrival performed maintenance. Inspected all electrical components, coils, pressures, and cleared drain line. Found both UV bulbs burnt out. Found the dual run capacitor reading weak MFD and the contactor pitted and burnt. Recommended on replacing these parts. We moved forward with the contactor and capacitor. The UV light cannot be found so we didn’t move forward on replacement of the bulb or a new UV system. Left system in good working order.
Dunedin, FL 34698
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos.
You and your service location:
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*
Back Next