Total Air Inc. has been serving the Allendale, FL, area since 2003 with professional home air conditioning service. We're quick and dependable when it comes to AC repair, and we offer full furnace and air conditioning services for your home. Our highly trained HVAC technicians are committed to keeping customers cool and comfortable. We offer:
- Air Conditioning Repairs
- Air Conditioning Installations
- Heating Repairs
- Heating System Installations
- Maintenance
- And More!
Our expert team is available 24/7 for any heating and air emergencies. When you first notice signs of your Allendale HVAC system acting up, don't hesitate to call us. We're quick and dependable, and we offer a 100% satisfaction guarantee on all of our work. Total Air is here to make sure you're cool and comfortable all summer long! Give us a call today at (727) 822-7700 for the best in air conditioning repair in Allendale FL!
Recent Jobs and Reviews
Job Locations and Reviews
Customer was concerned about the hissing noise that was coming from the outside unit. The noise the customer was hearing was coming from the compressor. Additional noise was coming from the condensing fan. When the system starts up, the fan was slow at starting. Customer agreed to speak with the comfort advisor to replace the system as the repair cost would be exceedingly expensive and their opinion.
System was partially frozen. Pressures are 166/168. I determined that the evaporator call is leaking refrigerant. Evaporator core and metering device needs to be replace. Customer agreed to move forward with the repair. Model Number tem4aoc60s51sba serial 2204s9n3v
Performed quoted repair. Pull and clean blower assembly and clean place evaporator coil. Completed maintenance on both systems once completed.
Per Marvin added refrigerant to Goodman System at no charge to the customer. System is cooling however, compressor is showing signs of decline. Compressor is running and I added estimate for warranty compressor once confirmed by the office. I suggest getting a comfort advisor to quote a new system versus investing into this one.
Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Removed debris from condenser unit and rinse condenser coil and compressor deck. Checked thermostat calibration and filter location. Customer has replaced filter. Cleaned and rinsed drain pan and drain line. Flushed drain line with water and primed drain line. Checked blower motor operation and inspected equipment cabinet. Located bad uv light in evaporator coil. Customer has approved for new uv light bulb replacement. Replaced light and checked refrigerant pressure in the system. Unit is cooling well and drains properly.
Customer has approved for membership renewal and uv light bulb replacement.
Thank you for choosing total air.
Next visit October 2024
New 16 inch return flex with new boot for increased airflow as designed, new metal duct cover, new thermostat, new hurricane pad with anchors and brackets, reuse disconnect box and electrical whip, new breakers as needed, all permits and inspections are included. upon arriving at jobsite meeting greet with customer go over work schedule for today start tearing out package unit and old pad, hand chisel away, concrete pad, 1 foot to fit new units pad in Platte River Rockwall around her level and to look nice rerun 14 inch supply under house flex rerun 14 inch return under house flex put to square to rounds on back of package unit hook up flex to squared around mastic seal everything complete hook up High-voltage and low-voltage g*******t 70 amp breaker. Call Perspex for 5KW heater start up unit checked and cool and emotes. Everything is going to factory specs.
Called out today due to no cooling.
Upon arrival system was running but the compressor was not. Found that the hard start has failed causing the compressor to not run.
Client approved hard start replacement.
Checked all electronics and motor components to ensure equipment is operating properly.
Checked filter.
Measured the temperature drop across the coil.
Checked refrigerant pressures.
Took amp draws.
Equipment is operating properly at this time.
Thank you for always choosing Total Air!
Water was dripping from a damaged, torn supply plenum box. The overflow drain pan was NOT full with water. After verifying refrigerate pressures, the gauges indicated an undercharge of r-410a, a refrigerant leak. Offered a recharge of r-420a & a electronic leak search be performed. Supply panel box would have to be redone over for a hole at the bottom where the water is leaking out from the frozen coils. Closely repairs outweigh replacement options on the 2014 air conditioner system. I strongly recommended speaking to comfort advisor about replacement options.
With costly repairs, it may be time to speak to a comfort advisor about a more efficient system
05/02/24 @ 11 to noon CA scheduled
Return to install warranty evaporator coil
Removed leak evaporator coil from air handler unit. Disassemble the drain pan and cleaned and rinsed drain pan. Installed new txv on new warranty evaporator coil replacement and installed evaporator coil in air handler unit. Weld copper and glued the drain line fittings. Nitrogen test for leaks and no leaks found. Pumped down evacuate the copper line set to 500 microns and release existing refrigerant to the system. Checked system operation and adjusted refrigerant pressure to 10 degrees sub cooling. Added 4 lb r410a refrigerant.
Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Removed debris from condenser unit and rinse condenser coil and compressor deck. Checked thermostat calibration and filter location. Customer has replaced filter
Called out today due to no cooling.
Upon arrival client stated that the condenser would not turn on.
Checked refrigerant pressures and found the system empty of charge.
Gave options for different leak searches as well as worst case scenarios for repairs.
Client is aware that the machine is 10 years old and out of manufacture warranty.
Made her aware that we can fix anything but offered her to weigh her options for repairs vs replacement.
She would like to speak with a comfort advisor about her options for replacement.
She is interested in moving the condenser to the side of the house.
Informed her of our financing options as well.
Left system in same condition as arrival.
Chris will be out from 3-4 with options for machine replacement.
Thank you for always choosing Total Air!
Giving quote for a Mini Split head In place coil cleaning, homeowner would like to call us back when he’s ready to do the work.
04/26/24 - NOT a Call back (DISPATCH please order the defrost board)
Bad defrost board. Bypassed the board to get temporary cooling. The low pressure switch is arcing against the suction line. Low pressure switch ohm out good but the wires need to be taped & tie wrapped away from the suction line.
04/30/24 - PART RETURN
Returned to install the defrost board under part’s warranty. I tie wrapped the low pressure switch that was arching against the suction line away from the lineset. Also, OHMED out the low pressure switch & it was still good. System is cooling properly at this time. Thank you for choosing Total Air… m
Remote for Daiken mini split not working properly screen fading away, was able to put the system on auto and gave option to sign up for maintenance to check and clean rest of system, homeowner agreed, signed up for 2 maintenance visits and performed one maintenance today, washed outdoor coil, checked refrigerant pressures and temperatures, rinsed and brushed filters to clean them, sprayed indoor coil with cleaner, and wiped mini split head inside, vacuumed drain but noticed it had fell off at the connection so I removed the panel and secured it and tapped it back in place and vacuumed drain again, remote needs to be replaced and homeowner will attempt to find one themselves first. Checked and tightened wiring, checked voltage, checked temperatures, all is operational at my departure except the remote control is not working properly. This job is completed, thank you for choosing total air.
Diagnosed call found blower motor not working
Went to pick up warranty blower
Performed pull and clean on blower
Cleaned coil in place
Flushed drain line
Install pure air uv
Checked refrigerant pressures.
Measured the temperature drop across the coil.
Paid with Check #3726
Enrolled in preventive maintenance plan.
Equipment is operating properly at this time.
Thank you for always choosing Total Air!
Called out today to perform a tune up.
V
Checked all electronics and motor components to ensure equipment is operating properly.
Flushed drain line with solvent.
Measured the temperature drop across the coil.
Tested float switch.
UV bulb is past due for replacement.
Outside I checked refrigerant pressures.
Contactor is pitted at the coil and buzzing when energized.
Took amp draws.
Removed the fan and cleaned the coil from the inside out.
Vacuumed drain line clear from outside port.
Gave options for preventative repairs and uv replacement.
New bulb is good for 12 months.
Equipment is operating properly at this time.
Thank you for always choosing Total Air!
Pumped down and reclaimed the existing refrigerant from condenser unit.
Removed/ weld low pressure switch and tested for leaks with nitrogen. No leaks present. Attached and secure wiring in place. Vacuumed system to 500 microns and refill with existing refrigerant that was reclaimed. Checked system operation and adjusted refrigerant pressure to manufacture specifications.
Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Checked thermostat calibration and filter location. Customer has provided filter replacement. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Removed debris from condenser unit and Cleaned and rinsed condenser coil and compressor deck. Checked ductwork connections and inspected attic insulation. Unit is cooling well and drains properly. Thank you for choosing total air.
Next visit September 2024.
Arrived and found thermostat blank, checked power to the thermostat and found it has power, checked thermostat and found pin broken in the back and thermostat not powering up, thermostat needs to be replaced. Quoted to replace thermostat with a $50 discount and membership discounts applied. Homeowner approved, replaced thermostat, programmed and tested system, all became operational, checked refrigerant and system is cooling at this time, high heat load inside, left system operational at my departure. Outdoor condenser fan motor is wobbly and noisy, could be a future repair. This job is completed for today, thank you for choosing Total Air
Upon arriving indoor unit was running and outdoor unit was running. System had 2.9 psi Gs in pressures. System is empty of refrigerant and is leaking from the evaporator coil. The compressor has been running in a vacuum for four days and has damaged the compressor. I provided customer with the estimate for repair cost to replace the evaporator coil and to replace the compressor. Customer opted to speak with a comfort advisor to get an estimate for immediate replacement. Customer would like for the system to be replaced as soon as possible. Sales appointment was set with Chris Garris.
Called out today due to no cooling.
Upon arrival the system would run but the compressor would not.
Checked all electronics and motor components.
Found that the capacitor has failed.
Replaced capacitor and tested system operation.
Checked refrigerant pressures.
Took amp draws.
Measured the temperature drop across the coil.
Blower wheel is heavily impacted with dirt and debris. I recommend removing the blower and cleaning the assembly.
Drain line is impacted with algae build up.
Blower is loud during operation.
I highly recommended preventative maintenance for the machine. Client declined and is aware of the current condition of the unit.
Equipment is operating at this time. This system can and will fail if cleanings and maintenance are not regularly performed.
Thank you for always choosing Total Air!
Water dripping by the air filter return grill, arrived at the house and was greeted by Autumn, she informed me of the situation with the water leak, I went into the attic where the air handler is and found safety float switch was not positioned correctly not allowing system to shut off on safety in case this kind of issue happened and the condensation drain is backed up with condensation water, informed this issue is due to lack on maintenance and that going forward maintenance needs to be done every 6 months. Quoted to flush drain with Drain Solve and sign up for the maintenance plan, waving service fee today, Autumn accepted option. I corrected safety float switch, replaced filter, cleared drain, added drain solve and flushed with hot water and vacuumed from outside, drain was really dirty and clogged with the Zoogloea bacteria, issue is corrected and system is operational and not dripping water anymore, this job is complete, Thank You for choosing Total Air.
Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Checked thermostat calibration and filter location. Customer has replaced filter. Cleaned and rinsed condenser coil and compressor deck. Checked refrigerant levels and check test start up components. The capacitor has tested good and working properly. Located the elite germicidal uvc light is weak and needs to be replaced. Customer has approved for elite uv light bulb replacement. Customer has 50$ coupon. I have replaced the uv light and collected for components replaced.
Unit is cooling well and drains properly. Thank you for choosing total air.
Customer has 50$ coupon
Next visit is October 29 2024
Called out today due to no cooling.
Upon arrival client stated that the air handler was running but the condenser was not.
Checked all electronics and motor components.
Found the capacitor swollen.
Replaced capacitor and checked system operation.
Checked refrigerant pressures.
Took amp draws.
Measured the temperature drop across the coil.
Checked filter.
Cleared drain line.
Vacuumed drain clear from outdoor port.
Gave options for repairs and preventative maintenance.
Waived service call fee for rescheduling.
Replaced capacitor with turbo.
Equipment is operating properly at this time.
Thank you for always choosing Total Air!
Bad OEM motor & module. A comfort advisor has been scheduled.
Comfort advisor has been scheduled….
Dispatch fee tech to the job
Bad 45/5mf capacitor. I recommend a replacement capacitor w/a hard start kit to help lower the compressor starting amps. Also, I recommend our Air Care Membership to save 20% off quoted repairs & cleanings & 2x system checks per year. Thanks for choosing Total Air…
REPAIRS PERFORMED
- Air Care Membership (senior) PD n FULL
-Remove & replacement of a 45/5mf cap
Arrived to call perform diagnostic found AirHandler running condenser not running, due to burnt high voltage wires found dead capacitor and wires to Contactor burnt. Also fix wiring issue change Contactor and change capacitor begin to start unit and found bad breaker breaker would not reset. Homeowner is going to replace breaker his self.
I return to perform recommended repair of evaporator coil replacement. I vacuumed the system down to 400 µm after pressure testing the system. Recharge the system to achieve a 9 to 10° superheat.