Allendale, FL

Request Service
Google Rating
4.8
Based on 1373 reviews
js_loader

Something is not working with with NN Extensions

Please Contact Local Gladiator For Support

Air Conditioning Repair and Services Near Allendale, FL

Total Air Inc. has been serving the Allendale, FL, area since 2003 with professional home air conditioning service. We're quick and dependable when it comes to AC repair, and we offer full furnace and air conditioning services for your home. Our highly trained HVAC technicians are committed to keeping customers cool and comfortable. We offer:

Our expert team is available 24/7 for any heating and air emergencies. When you first notice signs of your Allendale HVAC system acting up, don't hesitate to call us. We're quick and dependable, and we offer a 100% satisfaction guarantee on all of our work. Total Air is here to make sure you're cool and comfortable all summer long! Give us a call today at (727) 822-7700 for the best in air conditioning repair in Allendale FL!

Local Reviews

Total Air, Inc. Rated 4.9 out of 5 stars based on 1030 customer reviews

Map of St. Petersburg, FL 33714

Excellent Service




Review of Total Air, Inc.

Wade is always amazing and very knowledgeable. We request him every time and are extremely happy with the service and maintenance of this company. 10/10 would recommend.

St. PetersburgFL33714 27.8175-82.66

Map of Madeira Beach, FL 33708

Wonderful!




Review of Total Air, Inc.

Was very pleased with the service, Shaniya was very thorough and explained eveything so that I understood! Will definately be recommending and using in the future!

Madeira BeachFL33708 27.795-82.7875

Map of St. Petersburg, FL 33703

Outstanding Service




Review of Total Air, Inc.

I needed an emergency installation of AC as my 12 yr old unit was leaking. A friends company recommended Total Air as I was new to town and I will never regret calling them. The sales ppl came quickly and the installation of the new unit was quick as I was going out of town. The follow up service and maintenance is exceptional. The technicians I have dealt with are nothing but superb in their knowledge and job performance. I am 1000% satisfied with Total Air!!

St. PetersburgFL33703 27.8175-82.6325

Map of St. Petersburg, FL 33705

100% Perfect




Review of Total Air, Inc.

St. PetersburgFL33705 27.7825-82.655

Map of Gulfport, FL 33707

Good job




Review of Total Air, Inc.

GulfportFL33707 27.7525-82.7125

Map of St. Petersburg, FL 33705

Would not recommend Wade Hepp




Review of Total Air, Inc.

Wade was very nice but was at our home for about 4 total hours to fix a floater switch and unclog our drain. He also washed his tools in our bathtub without asking permission or telling us he was doing that and left a dirty mess in our tub and bathroom. Not sure if he was new as he had to make several calls during his visit to our home, but wound not not want him to return for our AC needs.

St. PetersburgFL33705 27.7225-82.63

Map of St. Petersburg, FL 33708

Excellent




Review of Total Air, Inc.

St. PetersburgFL33708 27.8225-82.7775

Map of St. Petersburg, FL 33713

Quick Service




Review of Total Air, Inc.

The technician came did a good job and was very efficient.

St. PetersburgFL33713 27.7725-82.695

Map of St. Petersburg, FL 33710

Excellent service!




Review of Total Air, Inc.

Anthony definitely knew what he was doing and was very pleasant to have in our home.

St. PetersburgFL33710 27.795-82.7075

Map of Treasure Island, FL 33706

Great service, very attentive and conscientious.




Review of Total Air, Inc.

Treasure IslandFL33706 27.7725-82.77

Helpful and on time!




Review of Total Air, Inc.

This is why I chose Total Air. They are helpful and do a great job!

GulfportFL33707 27.76-82.705

Top Notch !




Review of Total Air, Inc.

Top notch Tech! Came recommended from my next door neighbor. Fast customer service.

ClearwaterFL33761 28.03-82.73

Excellent service




Review of Total Air, Inc.

Tony did a FANtastic job!! Thank you

St. PetersburgFL33701 27.78-82.6375

On point. Precise. Excellent service




Review of Total Air, Inc.

Wade is extremely experienced. Knows his stuff. Excellent service.

St. PetersburgFL33712 27.7525-82.6675

Excellent Service




Review of Total Air, Inc.

Tony was very thorough.

St. PetersburgFL33703 27.815-82.6525

Wade H.

Wade H.

Membership maintenance. 6yr old Amana gas furnace and heat pump. Tested system function in cooling and in heating prior to completing any work. A/H- inspected all wiring and components. Flame sensor was covered in carbon. Cleaned and reinstalled flame sensor. Flushed and vacuumed drain line. Tested float switch. Blower wheel was heavily impacted with dust. I recommended a pull and clean to regain efficiency lost to dirty fan blades. Changed filter that was delivered to the job site. C/U- Checked capacitor microfarads. Took compressor amp draw. Checked refrigerant pressures and temperatures. Took Delta T temp split at supply and return registers. Based on the refrigerant pressures and temperatures, I believe the system may be undercharged. Spoke to the customer about leak search and adding refrigerant. Removed the air handler control board and wiring to reveal the blower. Removed blower wheel assembly. Removed motor. Washed blower wheel assembly with chemical cleaner until it was clean

Near 16th Ave N, St. Petersburg, FL 33710
Wade H.

Wade H.

Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked thermostat calibration and filter location. Customer has replaced filter. Checked electrical wiring and inspected cabinet condition. The evaporator coil is clean and free of debris. Air handler unit has good germicidal uvc light installed. Checked condenser unit and electrical disconnect. Checked electrical wiring and inspected electrical components. Test the capacitor and the capacitor is good and working properly. Checked refrigerant levels and check test start up components. Unit is cooling well and drains properly. Refrigerant pressure is good working properly. Recommend membership renewal for annual preventative inspections on ac systems. Customer has approved for membership renewal. Replaced customer provided f

Near 19th St N, St. Petersburg, FL 33714
Casey K.

Casey K.

7 new supply ducts, all connections sealed with mastic, reuse supply plenum.

Near 58th Way, Pinellas Park, FL 33781
Tony P.

Tony P.

No cool, no power to thermostat, also performed maintenance owed, homeowner is selling the house, proceeded to diagnose and found condensation float switch full of water, same issue as 6 months ago Greg and i discussed about previous history when I arrived, gave quote to flush condensation drain and add drain solvent and vacuum drain to clear it from outside, quote was accepted, flushed drain with hot water and vacuumed from outside, added drain solvent and drain is flowing and draining correctly at this time, vacuumed inside drain pan, proceeded to perform a system maintenance as well on the system since it’s almost time, checked refrigerant pressures and temperatures, checked temperature differential and coils, germicidal ultraviolet light ok and has kept system clean, checked all electrical components and moving parts, checked and tightened wiring, found outside unit has a loud rattle due to discharge pipe was rubbing on the bottom of the unit, corrected it today and placed video in

Near 18th St N, St. Petersburg, FL 33702
Wade H.

Wade H.

Membership maintenance. 6yr old ICP vertical – garage. A/H- flushed and vacuumed drain line. Tested float switch function. Checked all wiring. Unit has 3 OXY-PURE Air 24v lamps. Last replaced in 2022. Lights are dim and beginning to darken on the inside. I recommend replacement. Blower wheel and coil surface are clean/free of biological growth. Changed customer supplied return filter. Took temperature split at return and supply Plenum. C/U- noticed existing arma flex is dry rotting, and coil is beginning to corrode due to close proximity to the saltwater. Took compressor amp draw. Checked capacitor microfarad reading. Checked refrigerant pressures and temperatures. System is running well at this time. Replaced Armor flex on suction line at condensing unit. Installed corrosion grenade on liquid line at condensing unit.

Near Virginia Ave, Madeira Beach, FL 33708
Wade H.

Wade H.

Performed preventative maintenance tune up. Checked blower motor operation and inspected equipment cabinet. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked thermostat calibration and filter location. Customer has replaced filter. Checked electrical wiring and inspected cabinet condition. The evaporator coil is dirty and needs to be cleaned to help unit breathe properly. Checked rooftop condenser unit and electrical disconnect. Checked electrical wiring and inspected electrical components. Test the capacitor and the capacitor is weak. Recommend to capacitor replacement on condenser unit. Checked refrigerant levels and check test start up components. Unit is struggling to start up due to weak capacitor. Refrigerant pressure is good working properly. Due to aged equipment and failure on components. It may be time to speak with comfort advisor on upgrading the system to ener

Near Park Blvd, Seminole, FL 33777
Wade H.

Wade H.

Telli would like a quote for system replacement. She explained that the system was struggling last summer to keep up. I performed an attic inspection & found the duct work in good condition. Attic insulation is to county code r-38 value. Telli explained that her son’s bedroom is an hotspot of the home. Addition has been added to home so a heat load calculation will be needed to properly size the ac unit. Thank you for choosing Total Air…. It may be time to speak to Air Comfort Advisor about a more efficient air conditioner system.

Near 19th Ave N, St. Petersburg, FL 33710
Wade H.

Wade H.

Both indoor and outdoor units were running upon arrival. Temperature split of 6.4° with 75.5 coming out of the supply. System has a refrigerant leak which was visible inside of the condensing unit. I re-verified with electronic leak detector along with the customer. Customer decided to fill the system back up so they can cool for as long as they can until the work and repair is completed. Customer also approved for us to move forward with ordering the condensing coil. Model number CBA 25UH -036–230–01 serial number is 1519H19095.

Near Donato Dr, Belleair Beach, FL 33786
Casey K.

Casey K.

New plenums as needed, new float switches, new safety pan with rods and brackets, new breakers as needed, new hurricane pad outside with code approved anchors and brackets, flush and pressure test copper line set, new low voltage wiring to thermostat and outdoor system, all permits and inspections are included. New amana s thermostat.

Near Burlington Ave N, St. Petersburg, FL 33713
Wade H.

Wade H.

Customer concerned about unit not cooling properly. Checked blower motor operation and inspected equipment cabinet. The package unit is old and rusty components. Checked electrical wiring and inspected electrical components. The blower motor has been replaced and no safety surge protector on equipment. Checked thermostat calibration and filter. The thermostat is not working properly and needs to be replaced to keep unit cooling properly. Strongly recommend customer to speak with comfort advisor about upgrading the system to the energy standards of today’s equipment. Minimum repair is to replace the thermostat with new digital thermostat and 5 years warranty. Customer has declined services at this time. Sent out the estimate for thermostat replacement.

Near 62nd Ave N, Pinellas Park, FL 33781
Arionna L.

Arionna L.

Called out today due to no cooling. Upon arrival client stated that the system constantly runs. Checked all electronics and motor components. Checked airflow. Checked refrigerant pressures. System is low on charge. Gave options to refill the system and perform a leak search. I added a little over two pounds of 410 and performed a leak search. I found two pinhole leaks in the evaporator coil. Compared pressures and temperatures. System is cooling temporarily. The office will call the clients tomorrow and confirm the order for repairs Enrolled in preventive maintenance plan. Thank you for always choosing Total Air!

Near York St N, St. Petersburg, FL 33710
Wade H.

Wade H.

Customer concerned about unit not cooling properly. Checked blower motor operation and inspected equipment cabinet. Checked thermostat calibration and filter location. Customer needs to replace filter 18x14x1. Customer will retrieve filter. Located the thermostat has no power on display. Checked safety float switch and inspected low voltage wiring. Located the 5 amp fuse is tripped and needs to be replaced. I have set resettable fuse link and tested system operation. Checked refrigerant levels and check test start up components. The condenser is working properly and cooling well. Checked discharge temperature and inspected drain line. Unit has good safety surge protector on air handler unit to prevent voltage spikes on blower motor and heating contactor. I have replaced the 5 amp fuse and unit is running properly and cooling well. Thank you for choosing total air.

Near 84th Ave N, St. Petersburg, FL 33702
Wade H.

Wade H.

Return to install new 45 µF capacitor for the compressor. Old capacitor was reading outside of manufacturer recommended range. Restarted system after installing new capacitor.

Near Bougainvilla Ave S, St. Petersburg, FL 33707
Wade H.

Wade H.

System pressures exceeded manufacturing specs & is overcharged. The drain line Is backed up from dry sentiment in the drain line going to the Condensation pump. The condensation pumps float switch will not allow the air conditioner to run because of the blockage in the drain line. Recommended a new drain line be ran and recover all excess refrigerant.

Near 77th Ave N, St. Petersburg, FL 33702
Arionna L.

Arionna L.

Called out today for a part return to install a surge protector for the condenser. Installed surge protector. Informed client of operation and warranty. Equipment is operating properly. Thank you for always choosing Total Air!

Near 12th Ave S, Gulfport, FL 33707
Tony P.

Tony P.

Arrived at this call for system not cooling, upon arrival was informed by Miss Kimberly that she had a previous company that diagnosed a bad indoor fan delay board timer was bad, informed I’d do my own diagnosis and tested various system components including voltage and blower motor which are present, tested delay timer control board and set it to zero to test functions, found board is receiving 24 volts but the board is not sending 24 volts needed to the blower fan control going to the motor thus the motor is not running, tested motor by sending 24 volts directly to the blower motor and the blower motor came on. Quoted to replace the blower motor fan delay timer and sign up for out maintenance plan, quote was accepted, we sent our runner out to go get it and wrong part was brought out, will need to order the correct part and return tomorrow between 10-12 and I’ll collect payment upon work completion. Return to install board in the air handler, followed manufactures diagram for the w

Near Yacht Club Dr, Treasure Island, FL 33706
Arionna L.

Arionna L.

Called out today for a return cleaning. Removed and disassembled blower wheel compartment. Cleaned blower wheel and scrubbed fins. Wiped down blower housing. Reassembled blower compartment. Tested system operation before departure. Equipment is operating properly at this time. Thank you for always choosing Total Air!

Near 80th St N, St. Petersburg, FL 33709
Wade H.

Wade H.

Customer concerned about unit not cooling properly. The downstairs is way cooler than upstairs. I have replaced the evaporator coil and new txv with pvc fittings. The air handler unit is working properly and refrigerant pressure is good. The zone controller is working at each one to call for each zone. Upstairs zone #2 is working properly (video taken) Downstairs zone #1 is not closing the damper. The damper is remaining open and over cooling the downstairs zone #1 The damper motor is bad and needs to be replaced (video taken) Picked up new damper motor and installed to the damper duct. Checked system operation and each damper motor. Zone control and each damper is working properly and cooling properly. Thank you for choosing total air

Near Addison Dr NE, St. Petersburg, FL 33716
Wade H.

Wade H.

Full system maintenance. Checked refrigerant pressures and temperatures. Took Delta t temp split at return and supply register. Filter is clean. Air handler interior is clean with no dirt or biological growth. Flushed drain line with 1.5 L of water and the drain is clear. Compressor amp draw is good. Took microfarad reading on capacitor – capacitor is Over manufacturer limit of 35 µF reading at 180.7 µF I recommend replacement Returned to install warranty part. 35+5 MFD capacitor read 180/35 during maintenance so I recommend replacement. Installed new 35+5 capacitor and restarted the unit. System is running well at this time.

Near Bay St NE, St. Petersburg, FL 33703
Wade H.

Wade H.

Customer concerned about unit not cooling properly. Checked thermostat calibration and filter location. Checked outside condenser unit and new components replaced. The 24 volt contactor is not working again due to ants burnt out on the contactor. I have replaced the contactor and checked system operation. Unit is cooling well and running properly. Mentioned to customer that the area needs to be treated with insect repellent. Customer has approved for contactor replacement and membership renewal. Customer has paid in full. Thank you for choosing total air.

Near 8th Ave N, St. Petersburg, FL 33710
Wade H.

Wade H.

I return to install compressor. I pressure test at 154 psi‘s of nitrogen which held for 20 to 30 minutes. I vacuumed the system down to 300 µm to Paul in a deep vacuum. I recharge the system with 10.33 ounces of refrigerant to achieve a 10° subcool and a 13 to 14° superheat. As manufacturers recommendation.

Near 26th Ave N, St. Petersburg, FL 33704
Arionna L.

Arionna L.

Called out today due to no cooling. Upon arrival system was running but the compressor was not. Found a broken wire from the compressor and a melted capacitor. Replaced capacitor and repaired wire. Tested all electronics and motor components to ensure equipment is operating properly. Measured the temperature drop across the coil. Took amp draws. Enrolled client into preventative maintenance. Equipment is operating properly. Thank you for always choosing Total Air!

Near 1st Ave N, St. Petersburg, FL 33713
Tony P.

Tony P.

No cool call, was informed by Mr Henry that the indoor unit was cold the other day, diagnosed system has a failed blower motor, looked up warranties and system has a parts warranty until next year, quoted for a new blower motor under a parts warranty and quote was accepted, checked on parts availability and found it at a supplier about 30 minutes from here, went and got the motor and returned to replace the blower motor under a parts warranty and performed system maintenance, vacuumed drain, washed outdoor coil, inspected indoor coil, checked and tightened wiring, checked refrigerant pressures and temperatures and found system slighting low on refrigerant, quoted to add a couple lbs of refrigerant and to add a surge protector to the indoor unit, management approved complimentary refrigerant if surge protector gets installed today, installed surge protector and added 2 lbs of r410a refrigerant today, was able to get temperature split differentials go from 17 degrees to 20 degrees making

Near Hidden Brook Dr, Tampa, FL 33624
Wade H.

Wade H.

Chemcial cleaning on outdoor condensing unit. Condenser coil is full of dirt and debris. Removed outdoor fan assembly. Chemically treated condenser coil. After the first treatment, I noticed a lot of dirt coming out with the solution, so I decided to perform a second treatment. After the second round of chemical the coil was free of dirt. Reassembled condensing unit. restarted system.

Near 15th Ave N, St. Petersburg, FL 33704
Wade H.

Wade H.

New customer. Customer concerned about unit not cooling properly. Checked blower motor operation and inspected equipment cabinet. Checked thermostat calibration and filter location. Customer has replaced filter and the blower is working as normal. Checked safety float switch and inspected drain line. The drain line is cleared and safety float is working properly. Checked refrigerant levels and check test start up components. The capacitor has tested good and working. Located the system has no refrigerant pressure in the system. Added nitrogen and leak has been located at the evaporator coil in the air handler unit in the attic. Checked to see if unit is in warranty. Goodman Model # Aruf25b14ac Serial # 1910677122 Evaporator coil replacement plus 9 lb 410 refrigerant.

Near 50th Ave N, St. Petersburg, FL 33709
" state="[sa-state]" reviewcount="25" checkincount="25" zoomlevel="11" fblike="yes" mapscrollwheel="yes"]

Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos.
You and your service location:
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next