Book Now
Book Now

Treasure Island, FL Air Conditioning and Heating Services

Total Air, Inc.

Rated 5.0 out of 186 reviews

AC Repair Treasure Island, 33706

The Florida heat is nothing to play around with. We understand how crucial it is to have your AC working at full capacity to give you the most comfortable environment. That’s why AC repair is serious business and having a perfectly functioning Air Conditioner is so important. No matter how you may try to prevent any issues, it is bound to happen…There is no need to worry. Total Air Inc. provides expert Air Conditioner Tune-ups, AC preventative maintenance, and Air Conditioning Service and AC repair in Treasure Island, FL and surrounding areas at an affordable rate.

Treasure Island Air Conditioning Repair Experts

When the Florida heat pumps up, the last thing you need is for your air conditioning system to stop working. Sometimes your AC will act up and when it does, you can count on the quick and dependable AC Repair Service from Total Air Inc. We understand the importance of a fully functioning Air Conditioner and make your AC concerns a top priority.

At Total Air Inc. we are committed to keeping our customers in Treasure Island and throughout the Pinellas County area, cool and comfortable. Our experienced and highly trained HVAC technicians will provide the prompt, high quality air conditioning repair service needed to get your air conditioning systems up and running smoothly.

If your Air Conditioning unit is blowing hot air, making strange rattling sounds, or won’t turn on at all, give us a call here at Total Air Inc., (727) 822-7700. We will be there to solve any of your Air Conditioning problems. When it comes to Florida heat, AC Repair is crucial for any situation, large or small.

Local Reviews
for Treasure Island, FL

Total Air, Inc. Rated 4.8 out of 5 stars based on 5 customer reviews

Map of Treasure Island, FL

On time appointment




Review of Total Air, Inc.

Good service, on time, actually early, advance notice of arrival appreciated.


Map of Treasure Island, FL

Timely and friendly




Review of Total Air, Inc.

Nevin has helped us a few times. He is always on time, super-polite and explains everything well.


Map of Treasure Island, FL

Very good, thanks




Review of Total Air, Inc.


Map of Treasure Island, FL

Great




Review of Total Air, Inc.

Sergey was terrific. He fixed the drain and was very pleasant to me. A/c System is working fine now


Map of Treasure Island, FL

Excellent preventive maintenance!




Review of Total Air, Inc.

Diagnosed a bad capacitor and replaced it. This a avoided the AC breaking down when cooling becomes important in a few months. Excellent professional services provided by Total Air Inc and their technician. I highly recommend them.


Bryan F.

Bryan F.

Completed tune up on system. I checked all electrical components and motors. I cleared and primed drain line. I left system running with a 20 degree delta t. Uploaded pictures to service titan.

Near Paradise Blvd, Treasure Island, FL 33706
Justin A.

Justin A.

Cycled and inspected equipment. Upon arrival customer stated ECM blower motor wasn’t working and the wires to the transformer were burnt. Found blower motor working and system cooling upon arrival. Customer approved blower motor and declined wire repair. Left system in good working order for now. *note* system is 4-years old and should be under warranty. Will need to call manufacturer to verify warranty status and call customer with status and availability of install. Also added Alan Huntley cell# to notes section of this work order. *INSTALLER* please verify wire repair has been completed at transformer ( high voltage ) to avoid new motor prematurely failing. 7/2/2020 upon arrival replaced warranty blower motor. The wire repair has been completed and system is up and running. Cycled on and off made sure system came on every time. Left system in good working order.

Near 9th St E, Treasure Island, FL 33706
Brian R.

Brian R.

On arrival their was no code read. The code he got was P0 .. possibly bad IPM inverter board. I check condenser motor amps, good. The evap blower wheel is impacted. Larry will clean the wheel. If the code keeps coming back , need to order the condenser IPM board.

Near 3rd St E, Treasure Island, FL 33706
Brian R.

Brian R.

I found the drain line was restricted. I vacuumed out with cleaner. Flushed condensate pump too. I checked pressures and electrical components. Frank has a senior care.

Near 2nd St E, Treasure Island, FL 33706
Nevon H.

Nevon H.

Completed member tune up #2. I flushed and cleared the drain line, cycled and monitored the system. It was a little low on refrigerant and I added 1 lb of R427A. I checked for proper temperatures, pressures and electrical. I left the system in good running order.

Near Capri Blvd, Treasure Island, FL 33706
Justin A.

Justin A.

Upon arrival found the compressor and Outdoor fan not running due to failed 50+5 MFD capacitor. Also the system is completely empty on refrigerant. The 40 amp contactor was pitted and burnt as well. He wants to get an estimate on a new system so Bryan is coming out tomorrow between 9am-11am. System is not running.

Near Paradise Blvd, Treasure Island, FL 33706
Justin A.

Justin A.

Upon arrival performed maintenance on 2 systems. Inspected electrical components, coils, pressures, and filters. Cleared drain lines and primed the lines. Found that the downstairs blower motor was over amping. On further inspection found that both the capacitors were reading low MFD, and the contactors were pitted and burnt. Recommended on replacing the blower motor capacitors and contactors and installing surge protectors on both systems and we moved forward with the repairs. The capacitors come with a 5 year warranty and the surge protectors come with a 3 year warranty as well as an insurance of up to $7,500 on failure. Left systems in good working order.

Near 123rd Ave, Treasure Island, FL 33706
Brian R.

Brian R.

I performed a maintenance. The evap coil is covered in construction dust. I recommend a clean and pull which is 1/2 day. I checked electrical components, the contractor is pitted/ burnt,dual run capacitor is weak . I gave a quote on replacing the thermostat. I checked pressures,which the system is running on high head pressure due to the set up.. We discussed membership for $99 with 15% off and two maintenance visits.. Tom wanted me to email quotes..

Near Paradise Blvd, Treasure Island, FL 33706
Nevon H.

Nevon H.

Condenser dual capacitor failed and I replaced it (warranty). I cycled and monitored the system, checked for proper voltage, amps and pressures. I left the system in good running order.

Near Paradise Blvd, Treasure Island, FL 33706
Brian R.

Brian R.

Apartment #1: I found the blower bearings on the motor are failing which is making a thumping noise. We will email the quote tomorrow on a new motor with capacitor and blower wheel. I told the tenant not to run the a/c too much. It can fail anytime.. once the parts are installed, we need to test operation of system..

Near 116th Ave, Treasure Island, FL 33706
Sergey G.

Sergey G.

We completed tune up on system. We cleared the drain line and checked all electrical components. There was some bird damage on the suction line armaflex. The condenser capacitor was weak on herm, we presented it to the customer and he gave the go ahead with replacing the bad cap with a warranty cap. Checked the amp draw after replacing and everything check out fine. Uploaded the pictures to service titan and left the system in good working condition.

Near 1st St E, Treasure Island, FL 33706
Nevon H.

Nevon H.

Drain line was restricted and tripped the float switch. I flushed and cleared the drain line and float switch with approval. Customer says this has happened about 4 times now with the previous technician they had out. If it happens again, I recommend installing a condensate pump. I left the system in good running order.

Near 116th Ave, Treasure Island, FL 33706
Nevon H.

Nevon H.

Replaced the warranty condenser fan motor, checked for proper voltage, amps and temperatures. I left the system in good running order

Near 5th St E, Treasure Island, FL 33706
Tabatha S.

Tabatha S.

Install 2.5 Ton Heat Pump,Units Sit On Balcony, Re Use Thermostat, Seal All Plenums. Price Includes All Taxes, Labor And Permits Installed split system brand new copper line set brand new drain line pressure test and micron to factory specs unit working properly customer satisfied

Near Paradise Blvd, Treasure Island, FL 33706
Sergey G.

Sergey G.

I performed a complete tune up on ac system. And cleared the drain line with coil cleaner and water. I checked all electrical components and motors. Everything checked out to be in good working condition. The system was a little low on refrigerant ( R410A) I charged it with 1 pound of 410A refrigerant out of jug #126. Customer said that the unit wasn't cooling, the thermostat was set to heat. I switched it to cool and it worked. The customer also said that the thermostat would go blank sometimes. I think it's due to tripped float switch. I cleared the drain with nitrogen. I left the system in proper working condition.

Near Paradise Blvd, Treasure Island, FL 33706
Nevon H.

Nevon H.

Completed member tune up #1. I recommended replacing the uv light, we installed it in December of 2018 and has poor efficiency. Customer also wants a quote to replace the 12x8 supply grill in the hallway, it’s ugly and some rust. He is on a fixed income and would like to schedule the work for after the first of the month. He would prefer the same tech to come back and do the work. I left the system in good running order. The grille is the wrong type and size. It needs to be a 2 way supply register. (10 x 6 & 10 x 4 for proper sizing). (See picture). He wants us to install the uv light the same time with the register. I replaced the supply grill and the uv light. I recommended a pure air system but he declined at this time.

Near Paradise Blvd, Treasure Island, FL 33706
Sergey G.

Sergey G.

I went through the low voltage and found that the thermostat has failed. It's a communicating thermostat and we need to replace it with the same type of stat. I told the customer that we will be back when we get a new thermostat for him. Model # of stat is IF99-1292. I collected a service fee. I loaded my pictures to service titan and I entered the equipment information as well.

Near 1st St W, Treasure Island, FL 33706
Nevon H.

Nevon H.

Found airhandler run capacitor failed. I replaced it. Completed member tune up #2. Cycled and monitored the system in heat and cool mode and left it in good running order.

Near Paradise Blvd, Treasure Island, FL 33706
Brian R.

Brian R.

We checked pressures, added 1lb of 410a to be at factory specs.

Near Paradise Blvd, Treasure Island, FL 33706
Nevon H.

Nevon H.

Installed a Compressor Defender and a Elite UV system. Prerformed start up and both systems are working as intended. System running at the time of our departure.

Near Capri Blvd, Treasure Island, FL 33706
Tabatha S.

Tabatha S.

Install 4 ton 16 seer heat pump with 5 kw heat strips, unit will be removed by crane customer will pay them separately, near thermostat set up dehumidification, reline plenum, cap platform with plywood and metal install germicidal light. Price includes all labor, taxes and permits

Near Capri Blvd, Treasure Island, FL 33706
raiko@totalairinc.net

raiko@totalairinc.net

Upon arrival found the system low on refrigerant. I noticed oil at the air Handel liquid line and a visible leak with small bubbles from oil at a bracing point. I also noticed oil at the filter dryer bracing point. Recommendations Repair liquid line leak and replace the liquid line dryer. Charge up the system. One tech half day. Customer moved forward with suggested repairs. Performed the repairs, pressure test passed, and achieved under 500 vacuum. Performed start up and added 2 lbs of refrigerant. Left system in good working order.

Near 115th Ave, Treasure Island, FL 33706
Brian R.

Brian R.

I found the thermostat we installed in November failed. I replaced ( warranty). I inspected the system, found the condenser fan motor was over amping and the blower motor capacitor failed. I replaced parts. I couldn’t check proper pressures due to cold temps outside ( 48degs).. I talked to Ginger, we need to come back out to check pressure on a warmer day.. ( no charge)we need to arrange that with tenant. The air handler is from 2007 and the condenser is from 2013 ( mix). I left the system in good working order..

Near Paradise Blvd, Treasure Island, FL 33706