A Letter To Our Customers Regarding COVID-19

Contact Us
Specials
Book Now
Menu
Book Now
Book Now

Treasure Island, FL Air Conditioning and Heating Services

Total Air, Inc.

Rated 4.9 out of 456 reviews

AC Repair Treasure Island, 33706

The Florida heat is nothing to play around with. We understand how crucial it is to have your AC working at full capacity to give you the most comfortable environment. That’s why AC repair is serious business and having a perfectly functioning Air Conditioner is so important. No matter how you may try to prevent any issues, it is bound to happen…There is no need to worry. Total Air Inc. provides expert Air Conditioner Tune-ups, AC preventative maintenance, and Air Conditioning Service and AC repair in Treasure Island, FL and surrounding areas at an affordable rate.

Treasure Island Air Conditioning Repair Experts

When the Florida heat pumps up, the last thing you need is for your air conditioning system to stop working. Sometimes your AC will act up and when it does, you can count on the quick and dependable AC Repair Service from Total Air Inc. We understand the importance of a fully functioning Air Conditioner and make your AC concerns a top priority.

At Total Air Inc. we are committed to keeping our customers in Treasure Island and throughout the Pinellas County area, cool and comfortable. Our experienced and highly trained HVAC technicians will provide the prompt, high quality air conditioning repair service needed to get your air conditioning systems up and running smoothly.

If your Air Conditioning unit is blowing hot air, making strange rattling sounds, or won’t turn on at all, give us a call here at Total Air Inc., (727) 822-7700. We will be there to solve any of your Air Conditioning problems. When it comes to Florida heat, AC Repair is crucial for any situation, large or small.

Local Reviews
for Treasure Island, FL

Total Air, Inc. Rated 4.3 out of 5 stars based on 9 customer reviews

Map of Treasure Island, FL

Damaged unit




Review of Total Air, Inc.

Ordered a standard service for a system functioning properly and under warranty Tech arrived and found a “bad capacitor”. Stated it required repair and charged hundreds of dollars for the service. Shortly after departure, system started operating inefficiently Next day the system was unable to maintain cool temps during peak usage Called again. They sent out another team who tried to convince me this was coincidental and likely due to the storms. They were unable to complete repairs and said it would likely be between $1500-3500 to fix and would be able to get back on Monday when the parts center was open There were some red flags to me. I called another company for a second opinion. The tech showed up and nothin minutes found the issue. The original tech installed the wrong capacitor and it was damaging my system. Repairs were made and it is now functioning properly. Definitely suspicious


Map of Treasure Island, FL

Petty




Review of Total Air, Inc.

Jason said y’all don’t provide filters when doing semiannual scheduled service. That is unbelievably petty.


Map of Treasure Island, FL

Consistent quality service




Review of Total Air, Inc.

Jason came when needed and was comprehensive in determining what was wrong with our hvac. I have confidence Total Air will keep our systems running. Thank you.


Map of Treasure Island, FL

Excellent Service




Review of Total Air, Inc.

Excellent service by Total Air techs! Professional and knowledgeable. Thanks for a job well done!


Map of Treasure Island, FL

On time appointment




Review of Total Air, Inc.

Good service, on time, actually early, advance notice of arrival appreciated.


Map of Treasure Island, FL

Timely and friendly




Review of Total Air, Inc.

Nevin has helped us a few times. He is always on time, super-polite and explains everything well.


Map of Treasure Island, FL

Very good, thanks




Review of Total Air, Inc.


Map of Treasure Island, FL

Great




Review of Total Air, Inc.

Sergey was terrific. He fixed the drain and was very pleasant to me. A/c System is working fine now


Map of Treasure Island, FL

Excellent preventive maintenance!




Review of Total Air, Inc.

Diagnosed a bad capacitor and replaced it. This a avoided the AC breaking down when cooling becomes important in a few months. Excellent professional services provided by Total Air Inc and their technician. I highly recommend them.


matt@totalairinc.net

matt@totalairinc.net

All vents in home building up growth due to older duct work remaining in place with a new unit that is blowing almost 2000 cfm through the ducts mixing up all the existing growth in the unit. Customer has multiple additions on the home where duct work was just slapped on existing supply plenums and ran to these areas. Customer also has rooms that are not receiving adequate airflow. Their are supply flexes resting on return flexes. Mixing boxes not having proper static pressure to disperse air evenly and no dampers on any flexes. Supply plenum needs to be resealed properly since their are air leaks coming out. Moving forward Corey will be giving an estimate on a full duct replacement 12-2 on Friday. The only other option on this unit is to get a full duct cleaning, install a UV light, and adjust fan speed accordingly to drive any humidity down. I don’t recommend that route because this is not a for sure fix and will not help the rooms not receiving proper airflow. On top of any repair

Near 6th St E, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Upon arrival customer showed me a ac unit on the patio that needed tuned up. The evap coil is clean. Cleared condensate with nitrogen, solvent and water. Checked for proper amp and volts. The condenser is in the same close. He led all amps volt. Found a week capacitor. Replaced the capacitor. We have a Delta T of 18

Near Paradise Blvd, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Upon arrival customer told me the thermostat keeps going up in temperature. I turn the thermostat on and the out door unit cam on. Compressor and the fan did. I pulled the cover off the air handler and found the coil frozen and the motor not running. The motor is a ECM. I put my ECM test on and sent 24 volt to the motor and the motor did not come. The air handle motor needs to be replaced. The unit is for the downstairs. The unit is only 3 years old. Customer is wondering if it is under warranty

Near 6th St E, Treasure Island, FL 33706
Justin A.

Justin A.

Found condenser breaker tripped upon arrival. Flipped breaker and it immediately tripped again. Went to the condenser and took the load out of the circuit completely and the breaker wouldn’t trip. Then introduced the current just to the fan motor and the breaker would stay on. Checked the compressor to ground and it was okay, checked between the windings and it was okay, determined it was in a lock rotor state as soon as voltage was applied. Compressor harness was reading exact voltages when not applied as well. Need to order new compressor, refrigerant will need to be recovered and then pumped back in after replacement, recommend 2 guys 3-4 hours since we are lifting a compressor onto a roof through a tight access hole. Left system in the same state that I arrived and disconnect is upside down and off at the condenser.j 9/23/21 Returned to customers home to perform warranty work. Reclaimed all the refrigerant from the system. Disconnected the old compressor and filter drier. Instal

Near 104th Ave, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Amana ASZ14 Heat Pump 2.5 TonInstall 2 1/2 ton 14 seer Amana split system heat pump air handler on brand new plywood Stan top modified supply Plenum and he chilled insured Plenum was sealed properly added extra pieces to raise Plenum to fit on top of a new air handler/copper flush drain installed UV light and air handler float switch Honeywell T6 thermostat and change breakers accordingly 35 amp for air handler and 38 for condenser condenser on existing platform start it up and charge system to factory spec insured system is operating properly and walk customer through on how to operate their brand new HVAC system insured customer was fluent with herNew system customer paid balance in full job is complete customer satisfied

Near Gulf Blvd, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

System not cooling due to being completely out of refrigerant. The system is no longer under warranty so moving forward we will need to do a leak search on the system, I found signs of oil in the evaporator coil but we will need to verify to properly diagnose the system. If we go that route whichever coil the leak is present will need to be replaced and 8 pounds of Freon will need to be added to the system. Due to the age of the equipment and the condition I recommend full system replacement at this time, with a fresh 10 year warranty. Corey is scheduled for an 11-1 arrival time to present a free estimate to the customer.

Near Marina Terrace, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Upon arrival found thermostat not operating, recommended replacing thermostat, customer said they will take care of it themselves. Office needs to call to collect the service call fee. Performed systems first maintenance. Left system in same condition.

Near Paradise Blvd, Treasure Island, FL 33706
Justin A.

Justin A.

Upon arrival added 8x6 supply boot to bathroom and register, removed existing 6” flex duct and replaced with new 6” flex duct. Sealed duct to supply box and new 8x6 supply boot. Left system in working order.

Near 6th St E, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

System not cooling due to a thermostat failure. Verified thermostat failure by jumping it out and letting condensing unit kick on. Replaced thermostat and verified unit was running properly at this time.

Near 2nd St E, Treasure Island, FL 33706
Justin A.

Justin A.

Found condenser breaker tripped upon arrival. Flipped breaker and it immediately tripped again. Went to the condenser and took the load out of the circuit completely and the breaker wouldn’t trip. Then introduced the current just to the fan motor and the breaker would stay on. Checked the compressor to ground and it was okay, checked between the windings and it was okay, determined it was in a lock rotor state as soon as voltage was applied. Compressor harness was reading exact voltages when not applied as well. Need to order new compressor, refrigerant will need to be recovered and then pumped back in after replacement, recommend 2 guys 3-4 hours since we are lifting a compressor onto a roof through a tight access hole. Left system in the same state that I arrived and disconnect is upside down and off at the condenser.

Near 104th Ave, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Upon arrival performed maintenance, inspected electrical components, pressures, coils and drain line. Found weak dual run capacitor, recommended replacement, customer moved forward with replacement. UV light working properly. Renewed membership. Emailed customer. Left system in working order.

Near Paradise Blvd, Treasure Island, FL 33706
Justin A.

Justin A.

Upon arrival found drain line clogged. Cleared drain line and extended the float switch PVC so it would no longer be trapped under the refrigerant lines. Inspected operations after. Left system in working order.

Near Bayshore Dr, Treasure Island, FL 33706
Antonio D.

Antonio D.

Two air handler inspections complete volts amps are within range filters have been changed drains have been cleared. Two condensers have been serviced volts amps microfarads and refrigeration are all within range, recommend cleaning of one condenser client agreed work has been completed. Tuneup complete both units are operational at this time. Electrostatic filters to be changed next visit. Client wants supply in bathroom routed from a downward discharged to a side discharge this would require 12 to 15 feet of flex a metal 6 inch 90 and the original boot and a very small person suggest Casey, Office to provide estimate pricing to client for this work

Near 6th St E, Treasure Island, FL 33706
Justin A.

Justin A.

Upon arrival performed maintenance, inspected electrical components, pressures, coils, and drain lines. UV lights were working properly. Renewed customers membership, emailed customer. Left system in working order.

Near Paradise Blvd, Treasure Island, FL 33706
Jason D.

Jason D.

Cycled and inspected equipment. Found system not cooling during the heat of the day due to head pressure too high caused by salt deposits in condenser coil. I informed customer we could clean condenser coil but will most likely have to replace to resolve problem. Customer declined cleaning and requested quote to replace. Scheduled free estimate tomorrow 11-1 p.m. left system in same condition. Recommend: new equipment due to cost of repair, age, and overall condition of equipment.

Near 2nd St E, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Amana ASX14 AC 2 Ton. Install front draw unit on z bracket. Install uv light. Install t6 pro thermostat. Changed breakers according to size. Condensor installed on roof stand. Will need to schedule Inspection with customer. Customer satisfied!

Near 126th Ave, Treasure Island, FL 33706
Jason D.

Jason D.

Cycled and inspected equipment. Found system off on low temperature limit due to system set to 66°. Reset system and set thermostat to 69°. Left system in good working order.

Near Paradise Blvd, Treasure Island, FL 33706
Jason D.

Jason D.

Cycled and inspected equipment. Found condenser fan motor failed, dual capacitor weak, contactor pitted, and compressor drawing high amps. Condenser name plate has worn completely off and unit is dated from 1995. Customer requested quote to replace. Scheduled quote for today. Left system in same condition. Recommend: new equipment due to cost of repair, age, and overall condition of equipment.

Near 126th Ave, Treasure Island, FL 33706
Alex W.

Alex W.

Lennox system was not cooling due to water in aux. drain pan, removed water from aux. pan. Tested system for proper operation, left system in good working order at this time.

Near Dolphin Dr, Treasure Island, FL 33706
matt@totalairinc.net

matt@totalairinc.net

Upon arrival checked motors, electrical components, and pressures. DeltaT at 19 degree split. Cleared drain line and added Nubrite to system. Uploaded system information. AU blower motor had bio growth and let customer know about UV light Pure Air. Once I told him price he declined. Customer signed up for TAPS SENIOR LEFT SYSTEM IN GOOD OPERATING CONDITION.

Near 8th St E, Treasure Island, FL 33706
Jason D.

Jason D.

Required Repairs: These are the minimum services required to get your system running today and does not include any recommended actions that I noticed. Cycled and inspected equipment. Found breaker tripped due to a failing compressor ( over amping ). Also found evaporator coil dirty, run capacitor weak, dual capacitor weak, and contactor pitted. Reset breaker and compressor is currently running with high amps. Customer declined repair quote. Scheduled free estimate today.

Near Plaza Seville Ct, Treasure Island, FL 33706
Antonio D.

Antonio D.

Helped Antonio finish maintenance on condenser rooftop unit. Air handler inspection complete volts amps microfarads are within range, cleaned coil in place. Condenser inspection complete volts amps refrigeration are within range Tuneup complete

Near Capri Cir S, Treasure Island, FL 33706
Antonio D.

Antonio D.

System is down upon arrival condenser not condensing tested system found capacitor failed recommended replacement of capacitor client agreed. Found refrigeration low recommended leak stop and 2 pounds of 410 a refrigerant client agreed. This system is operational at this time.

Near Paradise Blvd, Treasure Island, FL 33706
Alex W.

Alex W.

Performed routine maintenance on Goodman split system checked amps volts pressures coils caps drain line etc. system is ok at this time

Near Gulf Blvd, Treasure Island, FL 33706
Jason D.

Jason D.

Required Repairs: These are the minimum services required to get your system running today and does not include any recommended actions that I noticed. Upon arrival customer stated the system was old, he understands the unit needs to be replaced, and he doesn't want to replace at this time. Customer also stated air handler is in a tight attic and he has removed some water from the pan, the unit is draining fine, and I didn't need to check the air handler at this time. After inspection of condenser only found dual capacitor was weak. Customer approved dual capacitor and declined system replacement and membership. Installed a new dual capacitor and left condenser cooling at this time. Recommend: new equipment to age and overall condition of equipment.

Near 2nd St E, Treasure Island, FL 33706

Schedule Service Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Would you like to upload photos?
Contact and Service Location...
You and Your Service Location
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next
Nearby Now Reviews
4.9
Based on 456 reviews